Zobrazeno 1 - 10
of 57
pro vyhledávání: '"Yu-Seok Kim"'
Publikováno v:
Science and Technology of Nuclear Installations, Vol 2016 (2016)
Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV), which can be obtained from high-energy (of tens MeV) accelerators. Instead of manufacturing an accel
Externí odkaz:
https://doaj.org/article/04051a7437b741f483301b874920a497
Publikováno v:
Journal of the Korean Physical Society. 82:257-262
Publikováno v:
Radiocarbon. 65:201-207
Radiocarbon (14C) in natural samples undergoes changes due to variations in atmospheric CO2 resulting from anthropogenic activities. To analyze the variation of the 14C ratio in atmospheric CO2, deciduous tree leaves were collected in Gyeongju, a pop
Publikováno v:
Journal of the Korean Society for Precision Engineering. 38:365-371
Publikováno v:
IEEE Transactions on Plasma Science. 49:298-301
A negative carbon-ion source has been designed and tested at the Dongguk University accelerator mass-spectrometer facility in Korea. The beam-extraction conditions in the ion-source test stand were determined experimentally. Negative carbon-ion beam
Publikováno v:
Journal of the Korean Physical Society. 77:425-428
Radiocarbon dating using a compact or low energy accelerator mass spectrometer has been rapidly developing in recent times. A gaseous ion source was designed and simulated to reduce sample preparation times. Then, a simulation study for low-energy ac
Publikováno v:
Journal of the Korean Physical Society. 76:613-616
The demand for radiocarbon dating using the accelerator mass spectrometer (AMS) is rapidly increasing. Accordingly, a system to inject gaseous samples directly into an ion source in order to measure isotopic ratios by using an Ams system is proposed.
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 465:15-18
A compact accelerator mass spectrometry (AMS) system dedicated to measuring 14C was installed at the Dongguk University, Korea. Standards SRM 4990B (Ox-I), SRM 4990C (Ox-II), IAEA C-7, and IAEA C-8 were used to conduct the acceptance tests. Phthalic
Publikováno v:
IEEE Transactions on Plasma Science. :1-5
A negative carbon-ion source was designed for accelerator mass spectrometry for application in the medical field to minimize cross-contamination and to increase the measurement efficiency. The ion source was designed by adjusting the distance between
Publikováno v:
Vacuum. 164:246-249
A gaseous ion source has been designed at Dongguk University accelerator mass spectrometer facility, Korea. Radiocarbon dating is conducted at this facility with a mini carbon dating system and a prototype ion source has been developed for a gas inje