Zobrazeno 1 - 10
of 164
pro vyhledávání: '"Yong Ping Zheng"'
Publikováno v:
Medicine in Novel Technology and Devices, Vol 11, Iss , Pp 100090- (2021)
Spinal deformities assessment using 3D ultrasound scanning has limitations in fitting onto different back surface contour as well as fitting within the gaps between subject and their spinal brace during bracing assessments. The study proposed a flexi
Externí odkaz:
https://doaj.org/article/efae72a202dc4abcb1eb676b45e95cf1
Publikováno v:
BMC Gastroenterology, Vol 24, Iss 1, Pp 1-12 (2024)
Abstract Background Non-invasive measurement of liver stiffness (LS), traditionally performed in the supine position, has been established to assess liver fibrosis. However, fibrosis degree is not the sole determinant of LS, necessitating the identif
Externí odkaz:
https://doaj.org/article/c7c761dfe3954ac6bc48160dbe401b6c
Autor:
Hongyu Kang, Xinyi Wang, Yu Sun, Shuai Li, Xin Sun, Fangxian Li, Chao Hou, Sai-kit Lam, Wei Zhang, Yong-ping Zheng
Publikováno v:
Bioengineering, Vol 11, Iss 9, p 889 (2024)
Transcranial sonography (TCS) has been introduced to assess hyper-echogenicity in the substantia nigra of the midbrain for Parkinson’s disease (PD); however, its subjective and resource-demanding nature has impeded its widespread application. An AI
Externí odkaz:
https://doaj.org/article/9c9d81eb890a449aacdc26865e6a64fa
Publikováno v:
Frontiers in Bioengineering and Biotechnology, Vol 12 (2024)
Background: Trans-spinal electrical stimulation (tsES) to the intact spinal cord poststroke may modulate the cortico-muscular control in stroke survivors with diverse lesions in the brain. This work aimed to investigate the immediate effects of tsES
Externí odkaz:
https://doaj.org/article/bcbd0ec85fef4be6bbdbd0a7883741b8
Publikováno v:
Bioelectronic Medicine, Vol 9, Iss 1, Pp 1-13 (2023)
Abstract Trunk stability is crucial for people with trunk paralysis resulting from spinal cord injuries (SCI), as it plays a significant role in performing daily life activities and preventing from fall-related accidents. Traditional therapy used ass
Externí odkaz:
https://doaj.org/article/8359ca7d9b5948b992ba0e969407a9ac
Publikováno v:
Brain Sciences, Vol 14, Iss 7, p 640 (2024)
Background: The recovery of locomotion is greatly prioritized, and neuromodulation has been emerging as a promising approach in recent times. Study design: Single-subject research design. Settings: A laboratory at The Hong Kong Polytechnic University
Externí odkaz:
https://doaj.org/article/f679c4586dc5417e87f41282098772c6
Publikováno v:
Bioelectronic Medicine, Vol 9, Iss 1, Pp 1-3 (2023)
Externí odkaz:
https://doaj.org/article/de0fd5bfe1ef4354a79daf42235242b2
Autor:
Tin Yan Lee, De Yang, Kelly Ka‐Lee Lai, Rene M. Castelein, Tom P. C. Schlosser, Winnie Chu, Tsz‐Ping Lam, Yong‐Ping Zheng
Publikováno v:
JOR Spine, Vol 6, Iss 3, Pp n/a-n/a (2023)
Abstract Background Three‐dimensional (3D) ultrasonography is nonionizing and has been demonstrated to be a reliable tool for scoliosis assessment, including coronal and sagittal curvatures. It shows a great potential for axial vertebral rotation (
Externí odkaz:
https://doaj.org/article/d4e88dac3ded4fa18f622a8d178797db
Autor:
Zi-Hao Huang, Li-Ke Wang, Shang-Yu Cai, Hao-Xin Chen, Yongjin Zhou, Lok-Kan Cheng, Yi-Wei Lin, Ming-Hua Zheng, Yong-Ping Zheng
Publikováno v:
Diagnostics, Vol 14, Iss 2, p 189 (2024)
Transient elastography (TE), recommended by the WHO, is an established method for characterizing liver fibrosis via liver stiffness measurement (LSM). However, technical barriers remain towards point-of-care application, as conventional TE requires w
Externí odkaz:
https://doaj.org/article/13c8ef04506b47e5940483ac11c4346f
Autor:
Ke-Jing Li, Nicky Lok-Yi Wong, Man-Ching Law, Freddy Man-Hin Lam, Hoi-Ching Wong, Tsz-On Chan, Kit-Naam Wong, Yong-Ping Zheng, Qi-Yao Huang, Arnold Yu-Lok Wong, Timothy Chi-Yui Kwok, Christina Zong-Hao Ma
Publikováno v:
Biosensors, Vol 13, Iss 12, p 998 (2023)
Falls are a prevalent cause of injury among older people. While some wearable inertial measurement unit (IMU) sensor-based systems have been widely investigated for fall risk assessment, their reliability, validity, and identification ability in comm
Externí odkaz:
https://doaj.org/article/cbf6711d4b344d04b80e6879576ed915