Zobrazeno 1 - 10
of 27
pro vyhledávání: '"Yeonok Park"'
Autor:
Changhwan Kim, Hojae Kim, Dongmin Jung, Heesoo Kim, Yeonok Park, Min Cheol Han, Chae-Seon Hong, Hojin Kim, Ho Lee, Jinsil Sung, Dong Wook Kim, Jin Sung Kim
Publikováno v:
Scientific Reports, Vol 14, Iss 1, Pp 1-12 (2024)
Abstract We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The
Externí odkaz:
https://doaj.org/article/8011d239f3714236bfba86f71bf16770
Publikováno v:
Med Phys
Purpose Scattered radiation is a major cause of image quality degradation in flat panel detector-based cone beam CT (CBCT). While recently introduced 2D antiscatter grids reject the majority of scatter fluence, the small percentage of scatter fluence
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::be2dffb74767068e85ed77c0c2bf750d
https://europepmc.org/articles/PMC7965329/
https://europepmc.org/articles/PMC7965329/
Publikováno v:
Med Phys
PURPOSE We have been investigating two-dimensional (2D) antiscatter grids (2D ASGs) to reduce scatter fluence and improve image quality in cone beam computed tomography (CBCT). In this work, two different aspects of 2D ASGs, their scatter rejection a
Publikováno v:
Proc SPIE Int Soc Opt Eng
While two-dimensional antiscatter grids (2D grid) reduce scatter intensity substantially in Cone Beam Computed Tomography (CBCT), a small fraction of scattered radiation is transmitted through the 2D grid to the detector. Residual scatter limits the
Autor:
Guna Kim, Soyoung Park, Dongyeon Lee, Hyunwoo Lim, Kyuseok Kim, Yeonok Park, Chulkyu Park, Taeho Woo, Hunwoo Lee, Uikyu Je, Hyosung Cho
Publikováno v:
Journal of Medical and Biological Engineering. 38:129-137
In recent computed tomography (CT) reconstruction, iterative methods have been often used owing to the potential to provide three-dimensional (3D) images of superior reconstruction quality to common filtered-backprojection (FBP)-based methods. Howeve
Autor:
Hyosung Cho, Soyoung Park, Chulkyu Park, Guna Kim, Dongyeon Lee, Hyunwoo Lim, Taeho Woo, Yeonok Park, Kyuseok Kim, Uikyu Je, Hunwoo Lee
Publikováno v:
Research in Nondestructive Evaluation. 29:109-121
Digital tomosynthesis (DTS) has been widely used in both industrial nondestructive testing and medical x-ray imaging as a popular multiplanar imaging modality. However, although it provides some of the tomographic benefits of computed tomography (CT)
Autor:
Kyuseok Kim, Chulkyu Park, Hunwoo Lee, Hyosung Cho, Dongyeon Lee, Guna Kim, Hyunwoo Lim, Yeonok Park, Uikyu Je, Soyoung Park, Taeho Woo
Publikováno v:
NDT & E International. 84:11-19
We have established a high-voltage computed tomography (CT) system with a 1–3 MV LINAC x-ray generator for industrial nondestructive testing. However, reconstructed CT images are typically blurred, limiting its image performance, mainly due to the
Autor:
Sungil Choi, Soyoung Park, Heemoon Cho, Yeonok Park, Taeho Woo, Hyunwoo Lim, Kyuseok Kim, Hyosung Cho, Uikyu Je, Chulkyu Park
Publikováno v:
Radiation Physics and Chemistry. 127:147-154
In this work, we investigated a compressed-sensing (CS)-based deblurring scheme incorporated with the total-variation (TV) regularization penalty for image deblurring of high accuracy and adopted it into the image reconstruction in conventional digit
Autor:
Soyoung Park, Guna Kim, Kyuseok Kim, Hyunwoo Lim, Taeho Woo, Chulkyu Park, Hunwoo Lee, Uikyu Je, Hyosung Cho, Dongyeon Lee, Yeonok Park
Publikováno v:
Instrumentation Science & Technology. 45:248-258
An industrial x-ray inspection system has recently established by our group to examine large and dense objects available in industry. It consists of an industrial x-ray generator having a tube voltage of 450 kV and a focal spot size of 1 mm, a flat-p
Autor:
Soyoung Park, Guna Kim, Kyuseok Kim, Yeonok Park, Jin-Soo Kim, Hyosung Cho, Jin Won Kim, Taeho Woo, Nagkun Chung, Jinguk Kim, Uikyu Je, Chulkyu Park, Hyunwoo Lim
Publikováno v:
Measurement. 91:634-640
We have recently developed very precise carbon-interspaced antiscatter grids having a wide range of grid strip densities ( i.e. , 85–234 lines/in.) by adopting the sawing process, depending on the demands of specific imaging modalities. However, be