Zobrazeno 1 - 10
of 43
pro vyhledávání: '"Yasin Kisioglu"'
Autor:
Serkan Aktas, Yasin Kisioglu
Publikováno v:
Materials Testing. 64:1012-1025
This study was aimed to produce and test dental implants made out of biocompatible commercial pure titanium (Grade 4) material with improved mechanical strength. The implant samples were designed and manufactured in real sizes using both machining an
Publikováno v:
Australian Journal of Mechanical Engineering. :1-11
Publikováno v:
Journal of Mechanical Materials and Mechanics Research. 6
The drilling process in orthopedic surgery can sometimes lead to an undesired increase in temperature, which can cause serious damage to bones and soft tissues. This overheating is typically identified as a temperature above 47°C, known as the criti
Autor:
Serkan Aktas, Yasin Kisioglu
Publikováno v:
Materials Testing. 62:1017-1024
Bolt production with a grade of 10.9 class quality made from AISI4140 material with a low thread rolling index is usually implemented in accordance with the thread rolling method (cold forming) in industrial applications. In this method, the effects
Autor:
Yasin Kisioglu, Talip Çelik
Publikováno v:
Politeknik Dergisi. 23:81-84
Ortopedi ve diş hekimliği alanında kullanılan implant ve protezlerde en sık karşılaşılan problem gevşeme problemidir. Bu sorun sebebi ile implantlar ve protezler işlevlerini yerine getiremez hale gelir. Bu gevşeme sorunun ameliyat sonras
Publikováno v:
Journal of Advanced Manufacturing Systems. 18:583-594
Heat reveals during the bone drilling operations in orthopedic surgery because of friction between bone and surgical drill bit. The heating causes extremely important damages in bone and soft tissues. The heating has a critical threshold and it is kn
Publikováno v:
Australian Journal of Mechanical Engineering. 19:261-267
In this study, effects of the Dynamic Hip Screw (DHS) positions on its failure are investigated in unstable femur fracture using Finite Element Analysis (FEA). The failures of DHS were emphasised i...
Publikováno v:
Journal of the Brazilian Society of Mechanical Sciences and Engineering. 43
Overheating occurs during the bone drilling process using drill bits in orthopedic surgery. The temperatures frequently exceed 47 °C, usually accepted as critical value, since the bones and surrounding tissues burn and then cause the necrosis during
Autor:
Talip Çelik, Yasin Kisioglu
Publikováno v:
Australasian physicalengineering sciences in medicine. 42(4)
Cemented and cementless hip prostheses are used in total hip replacement surgery. Short, medium and long term success rates of these hip prostheses are controversial in the literature. Traditional cemented and cementless hip prostheses have advantage
Autor:
Yasin Kisioglu, Fuat Kartal
Publikováno v:
Journal of Pressure Vessel Technology. 139
In this study, fatigue performances of the vehicle toroidal liquefied petroleum gas (LPG) fuel tanks were examined to estimate the fatigue life and its failure locations using both experimental and finite element analysis (FEA) methods. The experimen