Zobrazeno 1 - 10
of 32
pro vyhledávání: '"Yannig Nedellec"'
Publikováno v:
Nanomaterials, Vol 14, Iss 6, p 545 (2024)
We describe the creation of a conductive microcavity based on the assembly of two pieces of carbon nanotube buckypaper for the entrapment of two enzymes, horseradish peroxidase (HRP) and glucose oxidase (GOx), as well as a redox mediator: 2,2′-azin
Externí odkaz:
https://doaj.org/article/1b581537e0d7487b9d376a0fe27d3c3f
Publikováno v:
Nanomaterials, Vol 12, Iss 14, p 2399 (2022)
A new concept of hollow electrode based on the assembly of two buckypapers creating a microcavity which contains a biocatalyst is described. To illustrate this innovative concept, hollow bioelectrodes containing 0.16–4 mg bilirubin oxidase in a mic
Externí odkaz:
https://doaj.org/article/478f0c031aad49cc8a5603e489cc7dbc
Publikováno v:
Electrochemistry Communications, Vol 122, Iss , Pp 106895- (2021)
The fabrication of bioelectrocatalytic protein electrodes by the simple compression of carbon nanotube and protein powders was investigated using a series of proteins including bilirubin oxidase (BOx), bovine serum albumin (BSA), catalase, cytochrome
Externí odkaz:
https://doaj.org/article/84df7c2a5e7644c6a20cfe0b667f24be
Autor:
Ilaria Sorrentino, Ilaria Stanzione, Yannig Nedellec, Alessandra Piscitelli, Paola Giardina, Alan Le Goff
Publikováno v:
International Journal of Molecular Sciences, Vol 21, Iss 11, p 3741 (2020)
A chimeric enzyme based on the genetic fusion of a laccase with a hydrophobin domain was employed to functionalize few-layer graphene, previously exfoliated from graphite in the presence of the hydrophobin. The as-produced, biofunctionalized few-laye
Externí odkaz:
https://doaj.org/article/24fadafe05714f228de83c32f50b376f
Autor:
Anastasiia Berezovska, Anne Meiller, Stéphane Marinesco, Yannig Nedellec, Fabien Giroud, Andrew J. Gross, Serge Cosnier
Publikováno v:
Bioelectrochemistry. 152:108435
Autor:
Pierre Agostini, Omar Elmazria, Serge Cosnier, Karine Gorgy, Chantal Gondran, Stefan Mc Murtry, Yannig Nedellec
Publikováno v:
Biosensors and Bioelectronics
Biosensors and Bioelectronics, Elsevier, 2021, 180, pp.113137. ⟨10.1016/j.bios.2021.113137⟩
Biosensors and Bioelectronics, Elsevier, 2021, 180, pp.113137. ⟨10.1016/j.bios.2021.113137⟩
A biosensor based on the release of the enzyme substrate from its structure was developed for the inhibitive detection of benzoic acid. A polyurethane support comprising two perforated microcapsules (800 μm in diameter) filled with methylene blue as
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f5cbdf599c3029aa11d857858a5343ca
https://hal.archives-ouvertes.fr/hal-03166627/document
https://hal.archives-ouvertes.fr/hal-03166627/document
Autor:
Emerson M. Girotto, Michael Holzinger, Yuta Nishina, Yannig Nedellec, Bridget Davies, Pierre Yves Blanchard, Paulo Henrique M. Buzzetti, Alan Le Goff, Andrew J. Gross, Serge Cosnier
Publikováno v:
ChemElectroChem
ChemElectroChem, Weinheim : Wiley-VCH, 2019, 6 (20), pp.5242-5247. ⟨10.1002/celc.201901666⟩
ChemElectroChem, Weinheim : Wiley-VCH, 2019, 6 (20), pp.5242-5247. ⟨10.1002/celc.201901666⟩
International audience; A particularly efficient redox mediator for electron transfer between FAD‐dependent glucose dehydrogenase (FAD‐GDH) and carbon nanotube (CNT) based electrodes can be obtained via electrosynthetic oxidation of pyrene in aqu
Autor:
Serge Cosnier, Paulo Henrique Buzzetti, Yannig Nedellec, Monica Brachi, Karine Gorgy, Chantal Gondran, Dan Shan, Redouane Borsali
Publikováno v:
ECS Meeting Abstracts. :2079-2079
For four decades, the functionalization of electrodes by biomaterials based on electrogenerated polymers, carbon nanotubes and / or nano-objects, was widely used in the field of analytical chemistry and energy conversion. Recently, we redesigned enzy
Autor:
Caroline Abreu, Yannig Nedellec, Alan Le Goff, Serge Cosnier, Olivier Ondel, Michael Holzinger, François Buret
Publikováno v:
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical, Elsevier, 2018, 277, pp.360-364. ⟨10.1016/j.snb.2018.09.033⟩
Sensors and Actuators B: Chemical, Elsevier, 2018, 277, pp.360-364. ⟨10.1016/j.snb.2018.09.033⟩
International audience; A disposable ovulation test is operated using a flow stack of 5 in series connected glucose biofuel cells giving an open circuit voltage (OCV) of 3.5 V. Such tests consume at total around 60 μWh of energy and in average 1.7 m
Autor:
Olivier Ondel, Michael Holzinger, Caroline Abreu, Serge Cosnier, Alan Le Goff, François Buret, Yannig Nedellec
Publikováno v:
Journal of Power Sources
Journal of Power Sources, Elsevier, 2018, 392, pp.176-180. ⟨10.1016/j.jpowsour.2018.04.104⟩
Journal of Power Sources, Elsevier, 2018, 392, pp.176-180. ⟨10.1016/j.jpowsour.2018.04.104⟩
International audience; Bioelectrocatalytic carbon nanotube pellets comprising glucose oxidase (GOx) at the anode and horseradish peroxidase (HRP) at the cathode were integrated in a glucose/H2O2 flow-through fuel cell setup. The porous bioelectrodes