Publikováno v:
In Case Studies in Construction Materials July 2023 18
Autor:
Yang Sung Lin, 林暘淞
102
Clinicians have experienced mini-implant loosening during treatment and have difficulty in placing a mini-implant at the optimal position as the anchorage source. For solving the above-mentioned problems, the purpose of this study was to de
Clinicians have experienced mini-implant loosening during treatment and have difficulty in placing a mini-implant at the optimal position as the anchorage source. For solving the above-mentioned problems, the purpose of this study was to de
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/2v25kh
Autor:
Yang Sung Lin, 林暘淞
96
Polymethylmethacrylate (PMMA) resin was used widely in the clinics as the matrix of provisional fixed partial denture. However the problem of the provisional fixed partial denture of traditional PMMA resin usually subjects to fracture because
Polymethylmethacrylate (PMMA) resin was used widely in the clinics as the matrix of provisional fixed partial denture. However the problem of the provisional fixed partial denture of traditional PMMA resin usually subjects to fracture because
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/mz6843
Autor:
Yang, Shih-Yuan, Chung, Hung-Pin, Yang, Sung-Lin, Chien, Tsai-Yi, Huang, Kuang-Hsu, Chen, Yen-Hung
Publikováno v:
In Optics Communications 1 March 2020 458
Publikováno v:
Applied Sciences, Vol 11, Iss 4, p 1898 (2021)
This study evaluates the biomechanical performance of a new multi-axial alveolar distractor using an animal study. The multi-axial alveolar distractor is designed with a ball and socket joint mechanism that can rotate up to 60° toward the buccal/lin
Externí odkaz:
https://doaj.org/article/25a70a06313c4557833fc253b7e136a1
Publikováno v:
Applied Sciences, Vol 10, Iss 10, p 3471 (2020)
In this study, we evaluate the influence of implant neck wall thickness and abutment screw size on alveolar bone and implant component biomechanical responses using nonlinear finite element (FE) analysis. Twelve internal hexagon Morse taper implant
Externí odkaz:
https://doaj.org/article/7ae8049796114119a80ffac8126fcab7
Publikováno v:
International Journal of Highway Engineering. 22:61-68
Publikováno v:
Journal of Dental Sciences, Vol 4, Iss 3, Pp 110-117 (2009)
The purpose of this in vitro study was to compare the fracture resistance and failure modes of CEREC endo-crowns with the CEREC classic designed crown supported with glass fiber-reinforced composite posts and composite cores. The influences of therma
Externí odkaz:
https://doaj.org/article/f337214ce25c4d7c89d3adce2a04d152
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Novel multi-axial alveolar distractor — Part I: Design, manufacture, and mechanical/functional tests
Publikováno v:
Journal of Cranio-Maxillofacial Surgery. 47:1682-1689
Purpose This study developed a novel multi-axial alveolar distractor and evaluated its safety and effectiveness by performing various mechanical tests and finite element (FE) analysis. Materials and methods A ball-and-socket joint with a high degree