Zobrazeno 1 - 5
of 5
pro vyhledávání: '"Y A, Meurisse"'
Autor:
Y. A. Meurisse, A Sirinelli, Eric Bergoënd, Paul Neville, Michel Marchand, Alain Mirza, Michel Aupart
Publikováno v:
Aortic Root Surgery ISBN: 9783798518681
Aortic valve disease is the most common cardiac valve condition in developed countries, and its prevalence increases with patient age, especially due to calcified aortic stenosis [24]. Although aortic valve replacement (AVR) remains the most effectiv
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::66121fba89e2985d712533e7d8cdba2d
https://doi.org/10.1007/978-3-7985-1869-8_31
https://doi.org/10.1007/978-3-7985-1869-8_31
Publikováno v:
The Journal of heart valve disease. 7(5)
In patients with small aortic annuli, the choice of prosthesis should be based on hemodynamics and valve durability. The Carpentier-Edwards pericardial valve offers good hemodynamic performance and long-term valve durability. We reviewed our 12-year
Publikováno v:
The Journal of thoracic and cardiovascular surgery. 113(3)
Objective: The first generation of pericardial valves was withdrawn from the market because of a high rate of premature failure. With an original design, Carpentier-Edwards pericardial valves promised improved results. Methods: One hundred fifty pati
Publikováno v:
The Journal of heart valve disease. 5(3)
The first generation of pericardial valves was withdrawn from the market because of an excessive rate of premature failure. With an original design, the Carpentier-Edwards pericardial valve promised improved results.From July 1984 to December 1993, 7
Autor:
M R, Aupart, X B, Dreyfus, Y A, Meurisse, S C, Rouchet, A L, Sirinelli, M D, May, M A, Marchand
Publikováno v:
The Journal of cardiovascular surgery. 36(4)
From July 1984 to December 1991, 641 Carpentier-Edwards pericardial valves were used in 585 consecutive patients. There were 420 aortic valve replacements, 121 mitral valve replacements, and 50 double valve replacements. Mean age was 65.5 +/- 12 year