Zobrazeno 1 - 10
of 43
pro vyhledávání: '"Xun-Zi Cai"'
Publikováno v:
Journal of Orthopaedic Surgery and Research, Vol 14, Iss 1, Pp 1-8 (2019)
Abstract Background The debridement, antibiotics, and implant retention (DAIR) procedure is an established therapeutic option for periprosthetic knee infections (PKI). However, the efficacy and the indication for this procedure are still controversia
Externí odkaz:
https://doaj.org/article/0096cbc329b74bb0837c7ed64d366c03
Publikováno v:
Journal of Orthopaedic Surgery and Research, Vol 13, Iss 1, Pp 1-9 (2018)
Abstract Background Postoperative squeaking in patients who applied the fourth-generation ceramic bearing in primary hip replacement has not been reported systematically; we aim to study the squeaking incidence in the fourth-generation ceramic bearin
Externí odkaz:
https://doaj.org/article/fbae1789ed5d4239ae4d440edb026158
Publikováno v:
International Journal of Endocrinology, Vol 2014 (2014)
Purpose. The aim of this study was to directly compare the efficacy and the safety of the two agents for postmenopausal women. Methods/Principal Findings. Electronic databases were searched for relevant articles that met our predefined inclusion crit
Externí odkaz:
https://doaj.org/article/6c51c9386b194f9594a7c8b7814e5794
Publikováno v:
The international journal of medical robotics + computer assisted surgery : MRCASREFERENCES. 18(3)
Previous articles about MAKO robotic-assisted total hip replacement (THR) were mainly in patients with comparatively normal anatomy.From July 2020 to June 2021, we performed MAKO robotic-assisted THR in three hip-fused patients. We assessed the accur
Autor:
Xun-Zi Cai, Yute Yang, Zhongli Shi, Haobo Wu, Jianqiao Hong, Bin Hu, Shigui Yan, Yangxin Wang, Zhi-Min Ying, Tiao Lin, Xiang Zhao
Publikováno v:
Journal of Orthopaedic Research. 37:1489-1497
Particle-induced implant loosening is a major challenge to long-term survival of joint prostheses. Administration of intermittent parathyroid hormone (PTH) has shown potential in the treatment of cases of early-stage periprosthetic osteolysis, while
Publikováno v:
International Journal of Medical Sciences
Aseptic loosening is the most common complication of joint replacement. Previous studies showed that acrylic bone cement loaded with a commercially-available alendronate powder (APAC) had good promise against wear debris-mediated osteolysis for preve
Publikováno v:
Journal of Orthopaedic Surgery and Research
Journal of Orthopaedic Surgery and Research, Vol 14, Iss 1, Pp 1-8 (2019)
Journal of Orthopaedic Surgery and Research, Vol 14, Iss 1, Pp 1-8 (2019)
Background The debridement, antibiotics, and implant retention (DAIR) procedure is an established therapeutic option for periprosthetic knee infections (PKI). However, the efficacy and the indication for this procedure are still controversial. Method
Publikováno v:
Experimental and Therapeutic Medicine
Low-intensity pulsed ultrasound (LIPUS), which has been previously reported to promote bone repair, is proposed to be a noninvasive form of therapy for the treatment of osteonecrosis. Bone fillers made from composite scaffolds have been demonstrated
Autor:
Chenhe Zhou, Zhi-Min Ying, Shigui Yan, Sihao Li, Yute Yang, Jiahong Meng, Fengfeng Wu, Bin Hu, Han-Xiao Zhu, Guangyao Jiang, Xiang Zhao, Zhongli Shi, Haobo Wu, Xun-Zi Cai, Xuewu Sun
Publikováno v:
FASEB journal : official publication of the Federation of American Societies for Experimental Biology. 33(2)
Postmenopausal osteoporosis is initiated by estrogen withdrawal and is characterized mainly by overactivated osteoclastic bone resorption. Targeting TNF receptor-associated factor 6 (TRAF6) or its downstream signaling pathways to modulate osteoclast
Publikováno v:
Journal of Orthopaedic Surgery and Research
Journal of Orthopaedic Surgery and Research, Vol 13, Iss 1, Pp 1-9 (2018)
Journal of Orthopaedic Surgery and Research, Vol 13, Iss 1, Pp 1-9 (2018)
Background Postoperative squeaking in patients who applied the fourth-generation ceramic bearing in primary hip replacement has not been reported systematically; we aim to study the squeaking incidence in the fourth-generation ceramic bearing and rel