Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Xuemin Sui"'
Publikováno v:
Case Studies in Thermal Engineering, Vol 45, Iss , Pp 102987- (2023)
The thermal storage of thermally activated building systems (TABS) demonstrates the advantages of intermittent operation, however, the existing studies rarely compared different intermittent schemes to determine the optimal one. Therefore, this study
Externí odkaz:
https://doaj.org/article/4c9ade9c1c7a471b8f50404c4b593bb4
Publikováno v:
Energies, Vol 13, Iss 7, p 1568 (2020)
The heat storage effect of the tube-embedded slab cooling system (TESCS) makes the intermittent operation feasible, a reasonable intermittent strategy can fully realize the energy saving effect. This paper purposes to optimize the intermittent contro
Externí odkaz:
https://doaj.org/article/be8435be7381467bad350436fac7cc14
Publikováno v:
Sustainability; Volume 15; Issue 7; Pages: 6111
Taking two typical subway stations in Xi’an as the research objects, the thermal environment and human thermal comfort of the station in summer were studied based on field measurements and a questionnaire survey. Based on the relative warmth index
Publikováno v:
Atmospheric Pollution Research. 10:1985-1993
In previous studies of pollutant dispersion around and inside urban street canyons, several kinds source shape assumptions were employed. However, the impact of source shape on pollutant transport in urban street canyon is barely concerned. As a dete
Publikováno v:
Journal of Building Engineering. 42:103040
In recent years, China is facing severe haze pollution in winter. More and more newly built residential buildings are installed with mechanical ventilation systems . In order to explore the system's application effect, this study selected a new typic
Publikováno v:
Energies; Volume 13; Issue 7; Pages: 1568
Energies, Vol 13, Iss 1568, p 1568 (2020)
Energies, Vol 13, Iss 1568, p 1568 (2020)
The heat storage effect of the tube-embedded slab cooling system (TESCS) makes the intermittent operation feasible, a reasonable intermittent strategy can fully realize the energy saving effect. This paper purposes to optimize the intermittent contro
Autor:
Xuemin Sui, Xu Zhang
Publikováno v:
Building Services Engineering Research and Technology. 37:66-84
This paper proposed to discuss some issues about indoor microclimate parameters design in radiant cooled residential buildings. Based on the thermal comfort model, the relationships between low mean radiant temperature and other thermal microclimate
Autor:
Xuemin Sui, Xu Zhang
Publikováno v:
Energy and Buildings. 49:499-508
The energy consumption of ceiling radiant cooling combined with air supply system of different cooling load sharing rates (CLSRs) in residential buildings in summer was analyzed. Two air supply strategies were considered, including the all outdoor ai
Publikováno v:
Building Services Engineering Research and Technology. 34:317-331
The performance of a residential radiant chilled ceiling system combined with an outdoor air handling unit under steady operating conditions in summer was tested, and the stable operating characteristics of this system were analyzed. Indoor thermal e
Autor:
Xuemin Sui, Xu Zhang
Publikováno v:
Engineering Review : Međunarodni časopis namijenjen publiciranju originalnih istraživanja s aspekta analize konstrukcija, materijala i novih tehnologija u području strojarstva, brodogradnje, temeljnih tehničkih znanosti, elektrotehnike, računarstva i građevinarstva
Volume 35
Issue 1
Volume 35
Issue 1
A residential floor cooling system was tested, and the indoor thermal environmental parameters during the stable operation period of the system were measured. Based on the measured data, the indoor thermal environmental characteristics were analyzed,