Zobrazeno 1 - 10
of 212
pro vyhledávání: '"Xing, Yuxiang"'
Rotational computed laminography (CL) has broad application potential in three-dimensional imaging of plate-like objects, as it only needs x-ray to pass through the tested object in the thickness direction during the imaging process. In this study, a
Externí odkaz:
http://arxiv.org/abs/2406.12943
With advanced X-ray source and detector technologies being continuously developed, non-traditional CT geometries have been widely explored. Generalized-Equiangular Geometry CT (GEGCT) architecture, in which an X-ray source might be positioned radiall
Externí odkaz:
http://arxiv.org/abs/2212.12143
Interior tomography is a typical strategy for radiation dose reduction in computed tomography, where only a certain region-of-interest (ROI) is scanned. However, given the truncated projection data, ROI reconstruction by conventional analytical algor
Externí odkaz:
http://arxiv.org/abs/2209.10350
Metal artefacts in CT images may disrupt image quality and interfere with diagnosis. Recently many deep-learning-based CT metal artefact reduction (MAR) methods have been proposed. Current deep MAR methods may be troubled with domain gap problem, whe
Externí odkaz:
http://arxiv.org/abs/2111.12983
Purpose: Grating-based imaging (GBI) and edge-illumination (EI) are two promising types of XPCI as the conventional x-ray sources can be directly utilized. For GBI and EI systems, the phase-stepping acquisition with multiple exposures at a constant f
Externí odkaz:
http://arxiv.org/abs/2103.11541
With the growing technology of photon-counting detectors (PCD), spectral CT is a widely concerned topic which has the potential of material differentiation. However, due to some non-ideal factors such as cross talk and pulse pile-up of the detectors,
Externí odkaz:
http://arxiv.org/abs/2007.09870
Autor:
Wu, Chengpeng, Zhang, Li, Li, Xinbin, Chen, Zhiqiang, Xing, Yuxiang, Zhu, Xiaohua, Gao, Hewei
For grating-based x-ray phase contrast imaging (GPCI), a multi-order moment analysis (MMA) has been recently developed to obtain multiple contrasts from the ultra-small-angle x-ray scattering distribution, as a novel information retrieval approach th
Externí odkaz:
http://arxiv.org/abs/1912.13196
Low dose CT is of great interest in these days. Dose reduction raises noise level in projections and decrease image quality in reconstructions. Model based image reconstruction can combine statistical noise model together with prior knowledge into an
Externí odkaz:
http://arxiv.org/abs/1910.06940
Helical CT has been widely used in clinical diagnosis. Sparsely spaced multidetector in z direction can increase the coverage of the detector provided limited detector rows. It can speed up volumetric CT scan, lower the radiation dose and reduce moti
Externí odkaz:
http://arxiv.org/abs/1910.03746
X-ray Computed Tomography (CT) imaging has been widely used in clinical diagnosis, non-destructive examination, and public safety inspection. Sparse-view (sparse view) CT has great potential in radiation dose reduction and scan acceleration. However,
Externí odkaz:
http://arxiv.org/abs/1804.04289