Zobrazeno 1 - 10
of 53
pro vyhledávání: '"Xavier Subirats"'
Publikováno v:
Advances in Sample Preparation, Vol 6, Iss , Pp 100063- (2023)
In this work, the characterization of several reversed-phase and HILIC chromatographic systems is presented by means of the Abraham's solvation parameter model, focusing on the impact of solute polarizability, dipolarity, hydrogen bonding, and molecu
Externí odkaz:
https://doaj.org/article/a0695aca80af424ca59e40a3c6dc85b1
Publikováno v:
Molecules, Vol 28, Iss 3, p 1372 (2023)
Common methods for hold-up time and volume determination in Reversed-Phase Liquid Chromatography (RPLC) have been tested for Hydrophilic Interaction Liquid Chromatography (HILIC). A zwitterionic ZIC-HILIC column has been used for the testing. The pyc
Externí odkaz:
https://doaj.org/article/4601e1018c8a443d95c06c3f2dce56ba
Publikováno v:
ADMET and DMPK, Vol 6, Iss 2, Pp 153-161 (2018)
In the present study a pressure-assisted MEEKC method with reversed-polarity using a conventional CE instrument with UV detection and uncoated fused silica capillaries is validated as a high-throughput methodology for the lipophilicity determination
Externí odkaz:
https://doaj.org/article/7a31f22806ae49d9a5fb46a8f7d6bf92
Publikováno v:
ADMET and DMPK, Vol 5, Iss 4, Pp 253-256 (2017)
In the present study the solubility-pH profiles of sibutramine free base and its hydrochloride salt were determined in the pH range between 2.0 and 9.5 by means of the recommended shake-flask method, and the solids collected were dried and studied by
Externí odkaz:
https://doaj.org/article/d29b0cabcd9446b0baef247c691ab6c9
Publikováno v:
ADMET and DMPK, Vol 2, Iss 2, Pp 98-106 (2014)
In 1997 Valkó et al. developed a generic fast gradient HPLC method, based on the calculation of the chromatographic hydrophobicity index (CHI) from the gradient retention times, in order to measure lipophilicity. We have enhanced the correlations be
Externí odkaz:
https://doaj.org/article/7643fd29186d4cee94fd44ace1acb5aa
Autor:
Shushan Harutyunyan, Mohit Kumar, Arthur Sedivy, Xavier Subirats, Heinrich Kowalski, Gottfried Köhler, Dieter Blaas
Publikováno v:
PLoS Pathogens, Vol 9, Iss 4, p e1003270 (2013)
Upon infection, many RNA viruses reorganize their capsid for release of the genome into the host cell cytosol for replication. Often, this process is triggered by receptor binding and/or by the acidic environment in endosomes. In the genus Enteroviru
Externí odkaz:
https://doaj.org/article/5b32ddfb74f640a095ca22f7da8fcd13
Autor:
Bastida, Ramon1, Alcoverro, Xavier Subirats2
Publikováno v:
Técnica Contable y Financiera. may2023, Issue 63, p8-19. 12p.
Publikováno v:
Molecules
Volume 28
Issue 3
Pages: 1372
Volume 28
Issue 3
Pages: 1372
Common methods for hold-up time and volume determination in Reversed-Phase Liquid Chromatography (RPLC) have been tested for Hydrophilic Interaction Liquid Chromatography (HILIC). A zwitterionic ZIC-HILIC column has been used for the testing. The pyc
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d4fd10fa8f114a1c12bd718e230c9211
http://hdl.handle.net/2445/194593
http://hdl.handle.net/2445/194593
Publikováno v:
Dipòsit Digital de la UB
Universidad de Barcelona
Universidad de Barcelona
The Abraham linear free energy relationship model has been used to characterize a hydrophilic interaction liquid chromatography (HILIC) silica column with acetonitrile/water and methanol/water mobile phases. Analysis by the model for acetonitrile/wat
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e724d96a3090acbf4bc84f8eb9816e64
http://hdl.handle.net/2445/190169
http://hdl.handle.net/2445/190169
Publikováno v:
Dipòsit Digital de la UB
Universidad de Barcelona
Universidad de Barcelona
A methodology for the estimation of the different phase volumes in HILIC is presented. For a ZIC-HILIC column the mobile phase volume (hold-up volume) is determined in several acetonitrile- and methanol-water compositions by a Linear Free Energy Rela