Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Xavier Audier"'
Publikováno v:
Optics Letters
Optics Letters, 2023, 48 (2), pp.423. ⟨10.1364/OL.467514⟩
Optics Letters, 2023, 48 (2), pp.423. ⟨10.1364/OL.467514⟩
A stimulated Raman microscope is conventionally performed by modulating either the pump or Stokes beam and demodulating the other. Here, we propose a double modulation scheme that modulates both beams at f m and 2f m . Exploiting aliasing and reducti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2c1f7e41e7b9a618fc3321c1ed9d6cd2
https://hal.science/hal-03928736
https://hal.science/hal-03928736
Autor:
Dan Oron, Siddarth Shivkumar, Matan Menahem, Hervé Rigneault, Maor Asher, Xavier Audier, Dekel Raanan, Omer Yaffe, Nicolas Forget
Publikováno v:
Advanced Chemical Microscopy for Life Science and Translational Medicine 2021.
Low frequency vibrations (< 200cm^(-1)) contain the structural information of molecules or the crystal lattice - making low frequency Raman imaging an ideal candidate to analyze heavy molecules, crystal formation etc. The longer integration times of
Publikováno v:
Opt Lett
We describe a simple approach to dispersion-free optical delay line design that provides very low aberration over an extended delay range. In this approach, we minimize aberrations by directing non-axial beam displacements along a line of symmetry bu
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::ce6274317fbe3a9fc48f5bf1d5b0db99
https://europepmc.org/articles/PMC7789958/
https://europepmc.org/articles/PMC7789958/
Publikováno v:
Optics Express
Optics Express, Optical Society of America-OSA Publishing, 2020, 28 (10), pp.15505. ⟨10.1364/OE.390850⟩
Optics Express, 2020, 28 (10), pp.15505. ⟨10.1364/OE.390850⟩
Optics Express, Optical Society of America-OSA Publishing, 2020, 28 (10), pp.15505. ⟨10.1364/OE.390850⟩
Optics Express, 2020, 28 (10), pp.15505. ⟨10.1364/OE.390850⟩
We report a shot noise limited high-speed stimulated Raman microscopy platform allowing to acquire molecular vibrational spectra over 200 cm−1 in 12 µs at a scan rate of 40kHz. Using spectral focusing together with optimized acousto-optics program
Autor:
Xavier Audier, Hervé Rigneault, Flora Poizat, Barbara Sarri, Fabrice Caillol, Marc Giovannini, Julien Wojak
Publikováno v:
Biomedical Vibrational Spectroscopy 2020: Advances in Research and Industry.
We present advances in coherent Raman imaging for gastrointestinal cancer detection. We use stimulated Raman scattering (SRS) combined with second harmonic generation (SHG) to reveal cell nuclei, cytoplasm and collagen simultaneously in human tissues
Publikováno v:
APL Photonics, Vol 5, Iss 1, Pp 011101-011101-13 (2020)
APL Photonics
APL Photonics, 2020, 5 (1), pp.011101. ⟨10.1063/1.5129212⟩
APL Photonics, AIP Publishing LLC, 2020, 5 (1), pp.011101. ⟨10.1063/1.5129212⟩
APL Photonics
APL Photonics, 2020, 5 (1), pp.011101. ⟨10.1063/1.5129212⟩
APL Photonics, AIP Publishing LLC, 2020, 5 (1), pp.011101. ⟨10.1063/1.5129212⟩
We revisit laser intensity noise in the context of stimulated Raman scattering (SRS), which has recently proved to be a key technique to provide label free images of chemical bonds in biological and medical samples. Contrary to most microscopy techni
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e4b742cf1fb553ae49a4c7b9b050a72e
https://hal.archives-ouvertes.fr/hal-02432553
https://hal.archives-ouvertes.fr/hal-02432553
Autor:
Rafaël Canonge, Cécile Cador, Didier Marguet, Marc Giovannini, Flora Poizat, Emma Simon, Fabrice Caillol, Julien Wojak, Barbara Sarri, Hervé Rigneault, Xavier Audier
Publikováno v:
Scientific Reports
Scientific Reports, Nature Publishing Group, 2019, 9 (1), pp.10052. ⟨10.1038/s41598-019-46489-x⟩
Scientific Reports, 2019, 9 (1), pp.10052. ⟨10.1038/s41598-019-46489-x⟩
Scientific Reports, Vol 9, Iss 1, Pp 1-10 (2019)
Scientific Reports, Nature Publishing Group, 2019, 9 (1), pp.10052. ⟨10.1038/s41598-019-46489-x⟩
Scientific Reports, 2019, 9 (1), pp.10052. ⟨10.1038/s41598-019-46489-x⟩
Scientific Reports, Vol 9, Iss 1, Pp 1-10 (2019)
Conventional haematoxylin, eosin and saffron (HES) histopathology, currently the ‘gold-standard’ for pathological diagnosis of cancer, requires extensive sample preparations that are achieved within time scales that are not compatible with intra-
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6258109d8a98afbc84da1a6a96f67360
https://hal.archives-ouvertes.fr/hal-02266919/document
https://hal.archives-ouvertes.fr/hal-02266919/document
Autor:
Hervé Rigneault, Géraldine Pénarier, Barbara Sarri, Jean Alié, Valérie Lavastre, Xavier Audier, Rafaël Canonge
Publikováno v:
Journal of Raman Spectroscopy
Journal of Raman Spectroscopy, Wiley, 2019, 50 (12), pp.1896-1904. ⟨10.1002/jrs.5743⟩
Journal of Raman Spectroscopy, 2019, 50 (12), pp.1896-1904. ⟨10.1002/jrs.5743⟩
Journal of Raman Spectroscopy, Wiley, 2019, 50 (12), pp.1896-1904. ⟨10.1002/jrs.5743⟩
Journal of Raman Spectroscopy, 2019, 50 (12), pp.1896-1904. ⟨10.1002/jrs.5743⟩
International audience; Stimulated Raman Scattering (SRS) imaging is used to probe active pharmaceutical ingredient exhibiting polymorphism within compact tablets. We show that few SRS images performed at selected wavenumbers allows to access both ac
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d0a33c4a447888f6f2c8c9ee7dc301b3
https://hal.archives-ouvertes.fr/hal-02341193
https://hal.archives-ouvertes.fr/hal-02341193
Autor:
Matthew Markham, Ruishan Liu, Daniel J. Twitchen, Linbo Shao, Yun-Feng Xiao, Marko Loncar, Xavier Audier, Mian Zhang, Anna V. Shneidman, Harpreet Kaur Dhillon
Publikováno v:
Advanced Optical Materials. 4:1075-1080
Publikováno v:
Optics Letters
Optics Letters, 2018, 43 (19), ⟨10.1364/OL.43.004763⟩
Optics Letters, Optical Society of America-OSA Publishing, 2018, 43 (19), ⟨10.1364/OL.43.004763⟩
Optics Letters, 2018, 43 (19), ⟨10.1364/OL.43.004763⟩
Optics Letters, Optical Society of America-OSA Publishing, 2018, 43 (19), ⟨10.1364/OL.43.004763⟩
International audience; High speed imaging is of utmost importance for video-rate live cell investigations or to study extended sample areas at sufficient spatial resolution within reasonable time scales. Improving the speed of single-focus stimulate
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::683e6f5b8d082887337ab3806c7ed93b
https://hal.science/hal-01885424
https://hal.science/hal-01885424