Zobrazeno 1 - 10
of 24
pro vyhledávání: '"Wener Lv"'
Publikováno v:
SLAS Technology, Vol 29, Iss 5, Pp 100184- (2024)
The advanced prostate biopsy robot system has broad application prospects in clinical practice, but due to the deformation and distortion between MR-TRUS (magnetic resonance transrectal ultrasound) images, it poses challenges in biopsy accuracy and s
Externí odkaz:
https://doaj.org/article/c25431f227754cbeab4d6f9b20093952
Autor:
Kichang Lee, Wener Lv, Conor D. Barrett, Aneesh Bapat, Antonis A. Armoundas, Richard J. Cohen, Tatsuya J. Arai
Publikováno v:
Journal of cardiovascular electrophysiologyREFERENCES. 32(5)
INTRODUCTION We previously introduced the inverse solution guidance algorithm (ISGA) methodology using a Single Equivalent Moving Dipole model of cardiac electrical activity to localize both the exit site of a re-entrant circuit and the tip of a radi
Autor:
Anna M. Galea, Maysun Hasan, Conor D. Barrett, Wener Lv, Gordon B. Hirschman, Kichang Lee, Antonis A. Armoundas, Richard J. Cohen, Tatsuya J. Arai, Maya E. Barley, Robert P. Marini, Alison Hayward
Publikováno v:
Springer US
We have developed a system that could potentially be used to identify the site of origin of ventricular tachycardia (VT) and to guide a catheter to that site to deliver radio-frequency ablation therapy. This system employs the Inverse Solution Guidan
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f63fb59964193fa861739778ddedd948
https://hdl.handle.net/1721.1/127822
https://hdl.handle.net/1721.1/127822
Autor:
Anna M. Galea, Wener Lv, Gordon B. Hirschman, Antonis A. Armoundas, Richard J. Cohen, Kwanghyun Sohn, Conor D. Barrett, Kichang Lee
Publikováno v:
Pacing and Clinical Electrophysiology. 37:1038-1050
Background We have introduced a method to guide radiofrequency catheter ablation (RCA) procedures that estimates the location of a catheter tip used to pace the ventricles and the target site for ablation using the single equivalent moving dipole (SE
Autor:
Anna M. Galea, Richard J. Cohen, Conor D. Barrett, Kristen LeRoy, Maya E. Barley, Kichang Lee, Evgeny Ter-Ovanesyan, Robert P. Marini, Gordon B. Hirschman, Antonis A. Armoundas, Wener Lv, Graham E. Voysey
Publikováno v:
Pacing and Clinical Electrophysiology. 36:811-822
Background We developed and evaluated a novel system for guiding radiofrequency catheter ablation therapy of ventricular tachycardia. This guidance system employs an inverse solution guidance algorithm (ISGA) using a single equivalent moving dipole (
Publikováno v:
Key Engineering Materials. :71-78
In case of mechanical system health monitoring, a need to develop normal-knowledge based novelty detection techniques is increasing. The negative selection algorithm, which is inspired from the operation mechanism of human immune system, is one of su
Publikováno v:
Key Engineering Materials. :617-624
The detection and characterisation of subsurface flaws in nonmetallic materials are very important for people’s health, lives, and environment. Possible damage must be detected early and reliably. A capacitive approach for detecting the subsurface
Autor:
Richard J. Cohen, Anna M. Galea, Alison Hayward, Kichang Lee, Wener Lv, Kwanghyun Sohn, Gordon B. Hirschman, Antonis A. Armoundas
Publikováno v:
IEEE journal of biomedical and health informatics. 18(1)
Radio-frequency catheter ablation (RCA) is an established treatment for ventricular tachycardia (VT). A key feature of the RCA procedure is the need for a mapping approach that facilitates the identification of the target ablation site. In this study
Autor:
Kichang, Lee, Wener, Lv, Evgeny, Ter-Ovanesyan, Maya E, Barley, Graham E, Voysey, Anna M, Galea, Gordon B, Hirschman, Kristen, Leroy, Robert P, Marini, Conor, Barrett, Antonis A, Armoundas, Richard J, Cohen
Publikováno v:
Pacing and clinical electrophysiology : PACE. 36(7)
We developed and evaluated a novel system for guiding radiofrequency catheter ablation therapy of ventricular tachycardia. This guidance system employs an inverse solution guidance algorithm (ISGA) using a single equivalent moving dipole (SEMD) local
Autor:
Wener Lv, Richard J. Cohen, Antonis A. Armoundas, Graham E. Voysey, Kichang Lee, Evgeny Ter-Ovanesyan
Publikováno v:
The FASEB Journal. 23