Zobrazeno 1 - 10
of 166
pro vyhledávání: '"Walter E. Pae"'
Publikováno v:
Case Reports in Transplantation, Vol 2012 (2012)
We report a case of severe hemolysis and pulmonary valve insufficiency (PI) following right ventricular support using a paracorporeal pneumatic pump (Abiomed, Danvers, MA, USA). We speculate that the high velocity jet of blood emanating from the outf
Externí odkaz:
https://doaj.org/article/95ff917a009148edac890307f36fffa4
Autor:
Ray Newswanger, Walter E. Pae, John D. Reibson, Choon Sik Jhun, Heidi Flory, William J. Weiss, Gerson Rosenberg, Jenelle M. Izer, Joshua Cysyk
Publikováno v:
ASAIO Journal. 68:791-799
Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump
Autor:
Jenelle M. Izer, Eric Popjes, Choon Sik Jhun, Gerson Rosenberg, Walter E. Pae, Joshua Cysyk, Ray Newswanger, William J. Weiss
Publikováno v:
ASAIO J
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip fo
Publikováno v:
Catheterization and Cardiovascular Interventions. 93
A 71-year-old male with multivessel coronary artery disease who underwent bypass with saphenous vein grafts to a Marginal branch and distal RCA and LIMA to LAD in 1988, DM II, atrial fibrillation on Coumadin, TIA, obstructive sleep apnea and pulmonar
Publikováno v:
ASAIO Journal. 61:127-132
The optimal timing of left ventricular assist device (LVAD) implantation in the management of advanced heart failure remains controversial. We hypothesize that in patients with cardiogenic shock, the severity of end-organ dysfunction as determined by
Autor:
Ranjit, John, Keith D, Aaronson, Walter E, Pae, Michael A, Acker, David R, Hathaway, Kevin B, Najarian, Mark S, Slaughter, Eric, Steidley
Publikováno v:
The Journal of Heart and Lung Transplantation. 33:1066-1073
Background Drive-line infections and sepsis lead to significant morbidity and even mortality in patients with ventricular assist devices (VADs). The HeartWare HVAD system is unique compared with other VAD systems in that it has a thin, flexible drive
Autor:
Edward R. Stephenson, Nicholas C. Cavarocchi, Linda J. Bogar, Michael M. Koerner, Aly El-Banayosy, Joel B. Durinka, Walter E. Pae, Chris Brehm, Hitoshi Hirose
Publikováno v:
ASAIO Journal. 60:189-192
Preexisting organ dysfunctions are known factors of death after placement of implantable mechanical circulatory support (MCS). Extracorporeal membrane oxygenation (ECMO) may able to stabilize organ function in patients with cardiogenic shock before M
Publikováno v:
Artificial Organs. 38:1-4
Autor:
Sameer Khan, Aly El-Banayosy, Christoph Brehm, Edward R. Stephenson, Michael M. Koerner, Walter E. Pae, Howard S. Weber
Publikováno v:
The Journal of Heart and Lung Transplantation. 32:659-663
may also be beneficial in correcting misimpressions. It is important to present objective, statistical information in keeping with the patient’s clinical profile, although the power of such information to counter bias introduced by patient-to-patie
Autor:
Ray Newswanger, Bryan Fritz, Richard B. Medvitz, Gerson Rosenberg, Valentin Izraelev, William J. Weiss, Dennis Hicks, Alan J. Snyder, Joshua Cysyk, Walter E. Pae, Eric G. Paterson, Branka Lukic
Publikováno v:
ASAIO Journal. 55:556-561
The design and initial test results of a new passively suspended Tesla type left ventricular assist device blood pump are described. Computational fluid dynamics (CFD) analysis was used in the design of the pump. Overall size of the prototype device