Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Wallace K. Wong"'
Publikováno v:
Cryo letters. 33(6)
Encapsulating insulin producing cells (INPCs) in an immunoisolation device have been shown to cure diabetes in rodents without the need for immunosuppression. However, micro-encapsulation in semi-solid gels raises longevity and safety concerns for fu
Publikováno v:
SPIE Proceedings.
Access to an internal calibration reference system during flight is an important requirement for contemporary remote sensing missions. L-3 Communications SSG-Tinsley has designed, built, and tested a novel internal calibration source based on ribbon
Autor:
Wallace K. Wong, Michael E. Curcio
Publikováno v:
SPIE Proceedings.
The potential benefit of combined spectral and spatial imagery in the classification/monitoring study of events and processes has created strong interest in the class of remote sensors identified as imaging spectrometers. The production and commercia
Publikováno v:
SPIE Proceedings.
We report performance measurements of a photodiode array Hadamard transform spectrometer (HTS) with a stationary entrance mask. The high throughput of the multi-slit, no- moving parts instrument is shown to yield a significantly higher S/N ratio than
Publikováno v:
SPIE Proceedings.
An electroless nickel plated over aluminum mirror was tested for BRDF and surface profiles at two stages: First, after a standard polish for optical figure, and second, after a `super finishing process' which is designed to minimize optical scatter.
Publikováno v:
SPIE Proceedings.
A 6-inch diameter aperture space-based visible telescope has been optimized to perform surveillance against the space background with earth albedo as a primary source of straylight. A three mirror off-axis anastigmat has been designed to cover a 1.4
Publikováno v:
SPIE Proceedings.
The contamination control of telescopes with the straylight-rejection capability is reviewed to identify the degradative effects of contaminant phenomena on the measurements. Three levels of optical contamination are discussed including bidirectional
Publikováno v:
Applied Optics. 33:75
Hadamard spectrometers are well known for their multiplexing and/or throughput advantages. Traditionally these instruments require moving entrance and/or exit masks. The performance of a breadboard photodiode-array Hadamard transform spectrometer wit
Publikováno v:
SPIE Proceedings.
Recent re-measurement of the Out-of Filed-of View-Rejection (OFVR) characteristics of the ZIP telescope #2 indicated that the Point Source Power Transmittance (PSPT) was increased by as much as a factor of 400 at one off-axis source orientation in co
Autor:
Wallace K. Wong, Roger A. Van Tassel
Publikováno v:
SPIE Proceedings.
A Hadamard transform spectrometer has been designed which uses a stationary Hadamard mask at the entrance plane of a holographic grating, photodiode array spectrometer. The mask contains 2N-1 slots where N is the number of resolution elements in the