Nuclear Engineering and Design. 24:393-409
Coolant mixing in a helically wire-wrapped, 217 pin, full-scale model of an LMFBR fuel assembly is presented. Salt-injection-conductivity techniques were employed, using water as the coolant. Over four hundred probes were concentrated in a one-sixth
An N-Reactor inlet connector piping break was investigated in a laboratory study to determine the effect of this break on the affected process tube`s thermal-hydraulic performance. A full-scale mock-up of the piping between the inlet and outlet riser
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0343a7165d202e6c54096f5c31f305db
https://doi.org/10.2172/10180341
https://doi.org/10.2172/10180341
Autor:
W.L. Thorne, G.M. Hesson
The purpose of this report is to present the results of an experimental program investigating the transient response of a BDF process tube to sudden plugging of the coolant stream. The program was directed toward determining the degree of protection
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::68d8ddd8d2c6dedb75d136ed014c4b8f
https://doi.org/10.2172/10187755
https://doi.org/10.2172/10187755
Autor:
W.L. Thorne, G.M. Hesson
This report presents the results of preliminary experiments of a program directed toward determining the limit of protection afforded by the Panellit system against gradual plugging of a process tube.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::f95a71c0d2ef552e2a66626a0ccb87c4
https://doi.org/10.2172/10187723
https://doi.org/10.2172/10187723
Current Panellit protection procedures, termed instability limits, come from calculations based on steady state experiments. However, the actual conditions in a process tube following a plugging occurrence sufficient to cause unstable flow are transi
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::ec37a8e91d49741f71c128cf24f83f54
https://doi.org/10.2172/10179442
https://doi.org/10.2172/10179442
Autor:
W.L. Thorne
The purpose of this report is to provide a brief written description of the facilities existing at Hanford for research and development in the fields of heat transfer and hydraulics.
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::b048b23731ec8af0528edee713907d06
https://doi.org/10.2172/10188953
https://doi.org/10.2172/10188953
Each tube of the PRTR is provided with flow monitoring equipment consisting of a venturi flow meter in the inlet piping, sensing lines containing valves, and a Panellit flow transmitter. The flow transmitter does three things: converts the pressure d