Zobrazeno 1 - 10
of 23
pro vyhledávání: '"W.G. Siegers"'
Autor:
W.G. Siegers, Annemieke Kolkman, Andrea M. Brunner, Dennis Vughs, C. Bertelkamp, R Hofman-Caris, Thomas L. ter Laak
Publikováno v:
Chemosphere. 214:801-811
Transformation products (TPs) can be formed from organic micropollutants in the water cycle through both biological and technological processes. Despite the TPs' potentially altered toxicity compared to their parent compounds, transformation processe
Publikováno v:
Hofman-Caris, C H M, Siegers, W, van de Merlen, K, de Man, A & Hofman, J 2017, ' Removal of pharmaceuticals from WWTP effluent: removal of EfOM followed by advanced oxidation ', Chemical Engineering Journal, vol. 327, CEJ-D-17-03620R1, pp. 514-521 . https://doi.org/10.1016/j.cej.2017.06.154
Wastewater treatment plants (WWTPs) throughout the Netherlands contain significant concentrations of pharmaceuticals (25–65 μg/L) and about 10–20 mg C/L dissolved non-biodegradable organic matter. By means of IEX mainly the humic acid fraction o
Autor:
Wim A. Oorthuizen, D.J.H. Harmsen, Andrea M. Brunner, Annemieke Kolkman, Thomas L. ter Laak, Milou M.L. Dingemans, Bram J. Martijn, W.G. Siegers, C. Bertelkamp, B.A. Wols
Publikováno v:
Science of The Total Environment. 705:135779
The ever-increasing production and use of chemicals lead to the occurrence of organic micro-pollutants (OMPs) in drinking water sources, and consequently the need for their removal during drinking water treatment. Due to the sheer number of OMPs, mon
Autor:
J Adamus, Geert-Jan Witkamp, C Maffezzoni, B. Hofs, S. Salvador Cob, F.E. Genceli Güner, W.G. Siegers, Emile Cornelissen
Publikováno v:
Desalination. 344:137-143
Reverse osmosis membranes are increasingly used in drinking water treatment. However, the production of a concentrate stream is the main disadvantage of its application. Increasing the recovery of the membranes in order to have the smallest amount of
Autor:
Ran Shang, Bas Heijman, Jingyi Hu, Luuk C. Rietveld, Emile Cornelissen, W.G. Siegers, Alexis Martin
Publikováno v:
Separation and Purification Technology. 129:25-31
To efficiently adsorb micropollutants from surface water and groundwater by activated carbon, the concurrent natural organic matter (NOM) was removed by anionic exchange resin (AER) to reduce the adsorption competition. The studied AER showed a great
Publikováno v:
Desalination. 299:28-34
The trans membrane pressure (TMP) increase due to fouling of an Al 2 O 3 microfiltration (MF) membrane by particles and natural organic matter in different water types is studied. Removal of non-purgeable organic carbon (NPOC), turbidity and UV extin
Autor:
W.G. Siegers, AJ Abrahamse, M Dignum, N Moreau, Gary L. Amy, Luuk C. Rietveld, A. Grefte, L.P. Wessels, Emile Cornelissen
Publikováno v:
Water Research. 42:413-423
Early elimination of natural organic matter (NOM) by ion exchange (IEX) in water treatment is expected to improve subsequent water treatment processes and the final drinking water quality. Nine anionic exchange resins were investigated to remove NOM
Publikováno v:
Water Supply. 6:171-178
The application of nanofiltration is growing rapidly in drinking water and wastewater treatment. The main problem during the operation of nanofiltration membranes is membrane fouling, part of which is due to the presence of Natural Organic Matter (NO
Publikováno v:
Water Supply. 2:103-108
Adsorption columns are widely used in drinking water treatment to improve a number of water quality parameters. Granular activated carbon filtration (GAC) can be used to decrease the concentration of DOC, colour, taste, odour and pesticides. Columns