Zobrazeno 1 - 10
of 40
pro vyhledávání: '"W.A. Elmore"'
Autor:
P.R. Leblanc, J.E. McConnell, G. Benmouyal, J. Burnworth, R. Ramaswami, P.J. Lerley, J.E. Waldron, J. Pinto de Sa, J. Mizener, S.E. Zocholl, S. Watansiriroch, M. Meisinger, K. Freirich, P.A. Kotos, M.S. Sachdev, W.M. Strang, W.A. Elmore
Publikováno v:
IEEE Transactions on Power Delivery. 14:868-872
This paper introduces the new standard "IEEE standard inverse-time characteristic equations for overcurrent relays". It provides an analytic representation of typical electromechanical relays operating characteristic curve shapes in order to facilita
Autor:
P. Waudby, P. Kerrigan, D.W. Smaha, M. Yalla, S. Easterday-McPadden, W. G. Hartmann, J. Hurley, S. Patel, M. Bajpai, K. Kozminski, G. Nail, J. Gardell, E. Fennell, A.C. Pierce, G. Pence, K. Khunkhun, W.A. Elmore, C.J. Mozina, C.W. Fromen, S. Usman
Publikováno v:
IEEE Transactions on Power Delivery. 14:132-141
The practice of tripping the generator breakers immediately following a boiler/turbine trip exposes a steam turbine generator to a potentially damaging overspeed operating condition. This paper describes the use of the sequential trip mode as a means
Autor:
J.E. Stephens, I.O. Hasenwinkle, J.D. Wardlow, W.G. Lowe, R. Hedding, E. Krizauskas, A. Darlington, M.J. McDonald, A.P. Apostolov, B. Jackson, W.A. Elmore, J. Boyle, K. Behrendt, S. Chano, T. Domin, W.M. Strang, R.W. Haas, S. Zocholl, L. Gray, P. Engel, H.M. Shuh
Publikováno v:
IEEE Transactions on Power Delivery. 14:116-125
Setting instantaneous overcurrent (IOC) relays on subtransmission lines has not been considered a complicated procedure by most utilities. However, undesirable operations have drawn attention to their intended function and application. This report ad
Publikováno v:
IEEE Transactions on Industry Applications. 29:404-411
The authors attempt to show, theoretically and by laboratory tests, the influence of harmonics on protective relays. Representative relays using various operating principles were tested using fundamental currents and/or voltages. They were then teste
Autor:
W.A. Elmore, C.A. Kramer
Publikováno v:
IEEE Transactions on Power Delivery. 5:915-923
The fundamentals of inverse time overcurrent relaying, recent changes in transformer characteristic curves, and a flexible microprocessor-based relay that has wide application possibilities are described. Insight into the process of selecting a parti
Autor:
A.C. Pierce, G. Nail, A.N. Darlington, C.L. Wagner, G.D. Rockefeller, L.E. Landoll, R.J. Fernandez, R.W. Haas, J.R. Gil-Berlinches, W.J. Marsh, L.S. Wright, W.A. Elmore
Publikováno v:
IEEE Transactions on Power Delivery. 5:575-584
The authors report on and analyze a survey of practices and experiences with time-delay back-up protection associated with unit-connected generators, predominantly rated 100 MVA and above. In addition, application and setting considerations are discu
Autor:
W.A. Elmore
Publikováno v:
58th Annual Conference for Protective Relay Engineers, 2005..
This paper describes the design constants of large generators and their influence on protective relaying. The detailed nature of machine impedances, fault currents, the phasor diagrams for round-rotor and salient pole machines, saturation curves and
Autor:
W.A. Elmore
Publikováno v:
57th Annual Conference for Protective Relay Engineers, 2004.
The literature is replete with guidance on the subject of bus relaying. Because of the extremely detrimental results of incorrect operation of bus differential relaying, those giving such guidance have generally leaned in the direction of security. T
Autor:
T.E. Wiedman, J. Berdy, H.O. Ohmstedt, A.N. Darlington, W.A. Elmore, G. Stranne, R.F. Arehart, C.J. Mozina, S. Conrad, H.G. Farley, A.C. Pierce, D.C. Mikell, F. Tajaddodi, E.T. Sage, G. Nail, L.J. Schulze, J.J. Bonk, D.E. Sanford, W.M. Strang
Publikováno v:
IEEE Transactions on Power Delivery. 4:965-977
The report considers the problem of inadvertent generator energization, the hazard to the generator and turbine, and the major dedicated protection schemes used within the industry to detect this condition. It is concluded that inadvertent energizing
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.