Zobrazeno 1 - 10
of 52
pro vyhledávání: '"W. H. L. Teoh"'
Publikováno v:
Anaesthesia. 65:1173-1179
We compared the efficacy of the inflatable cuff of the LMA Supreme against the non-inflatable i-gel cuff in providing an adequate seal for laparoscopic surgery in the Trendelenburg position in 100 female patients. There was no difference in our prima
Publikováno v:
Anaesthesia. 65:1126-1132
We compared the intubating characteristics of the Pentax Airway Scope, the C-MAC and the Glidescope with those of the Macintosh laryngoscope in 400 patients without predictors of difficult intubation. We found shorter intubation times with the Airway
Publikováno v:
Anaesthesia. 64:1172-1177
Summary We aimed to determine if using the EndoFlex® tracheal tube on the first intubation attempt provided improved placement times and intubation success compared with a standard-type tracheal tube in 50 patients undergoing gynaecological surgery
Publikováno v:
Anaesthesia. 64:1125-1129
Summary We compared intubating characteristics of the Pentax AirwayScope and Glidescope in a randomised controlled trial involving 140 patients. We found significantly shorter intubation times with mean (SD) 21.3 (12.3) vs 30.2 (13.2) s, lower intuba
Autor:
Y. Lim, W. H. L. Teoh
Publikováno v:
Anaesthesia. 62:381-384
We compared the times to intubate the trachea using the single use (Group S) and reusable (Group C) intubating laryngeal mask (ILMA(TM)), in 84 healthy patients with normal airways undergoing elective gynaecological surgery. There was no significant
Publikováno v:
Anaesthesia. 69(11)
Autor:
M. S. Kristensen, W. H. L. Teoh
Publikováno v:
Anaesthesia. 69(6)
Publikováno v:
Acta anaesthesiologica Scandinavica. 58(6)
We studied the hypothesis that an equal spinal anaesthetic dose administered in the sitting position to patients undergoing post-partum tubal ligation (PPTL) and caesarean section (CS) would yield similar sensory block characteristics and analgesic e
Publikováno v:
Acta anaesthesiologica Belgica. 64(4)
We report an exceptional case of secondary postpartum hemorrhage (PPH) twenty days after cesarean delivery, resulting from a ruptured uterine artery pseudoaneurysm (UAP). The diagnosis was initially confounded by a septic shock necessitating inotropi
Publikováno v:
Anaesthesia and intensive care. 40(4)
Due to the large number of videolaryngoscopes now available, it might be difficult for novice users to assess the various devices or use them optimally. We have collated the experiences of several airway management experts to assist in the assessment