Zobrazeno 1 - 10
of 1 461
pro vyhledávání: '"W. A. Chisholm"'
Publikováno v:
The British Medical Journal, 1977 Jul . 2(6082), 322-323.
Externí odkaz:
https://www.jstor.org/stable/20415431
Autor:
Ian Grant, Hong Chen, Sarma Nuthalapati, Tip Goodwin, Jake P. Gentle, Huu-Minh Nguyen, José Antonio Jardini, Charles Xu, Neil Hurst, Paula Traynor, W. A. Chisholm, Dale Douglass, Robert Kluge, Cody Davis
Publikováno v:
IEEE Transactions on Power Delivery. 34:2100-2109
Power flow, on both AC and DC overhead transmission lines, is limited to keep the conductor temperature below a maximum (TCMAX) specified to limit both conductor sag and the aging of conductors and splices over time. This power flow limit (line therm
Autor:
W. A. Chisholm, Farhad Rachidi, Carlo Alberto Nucci, Fabio Tossani, Alberto Borghetti, Fabio Napolitano
Publikováno v:
Lightning Interaction with Power Systems-Volume 2: Applications ISBN: 9781839530920
This chapter describes two of the most adopted software tools for the evaluation of the lightning performance of transmission and distribution lines, namely FLASH and LIOV-EMTP (Lightning Induced OverVoltage - ElectroMagnetic Transient Program), toge
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e660b482580d5085a9da2c6dec88dbe8
http://hdl.handle.net/11585/857206
http://hdl.handle.net/11585/857206
Autor:
Paulo Edmundo Freire, FR Lionel Figueroa, BR Oswaldo Regis, CA George Watt, José Antonio Jardini, W. A. Chisholm
Publikováno v:
2019 International Symposium on Lightning Protection (XV SIPDA).
The awareness of the potential safety risk is paramount in the safe operation of overhead transmission lines. The consequence of safety hazards from touch, step and transferred voltages due to Ground Potential Rise (GPR) cannot be ignored or under-es
Autor:
Keith Lindsey, Mohammad Pasha, Glenn Davidson, Peter Waltz, Tapani Seppa, Janos Toth, Tom McCarthy, Carlos Alexandre Meireles Do Nascimento, W. A. Chisholm, Dale Douglass, Dan Lawry, Jerry Reding, Mark Lancaster, Ian Grant
Publikováno v:
IEEE Transactions on Power Delivery. 31:921-927
This paper discusses the wide range of real-time line monitoring devices which can be used to determine the dynamic thermal rating of an overhead transmission line with the power system operating normally or during a system contingency. The most comm
Autor:
Clifton Black, W. A. Chisholm
Publikováno v:
IEEE Transactions on Power Delivery. 30:2154-2162
Recent reviews have shown that many methods can be used for estimating the dynamic thermal capacity of overhead transmission lines. A number of approaches are described and key features of each system are organized. Data from field trials provide a u
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 21:2531-2540
In February and December 2012, SaskPower experienced two flashovers of "clean" Fiberglass-Reinforced Plastic (FRP) hot stick during cold weather live-line work under steady-state 230 kV ac system conditions. As for SaskPower, Manitoba Hydro had two s
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 21:2628-2633
Controlled laboratory tests validated a hypothesis that extremely light (~2-3 μg/cm2) levels of Equivalent Salt Deposit Density (ESDD) with no Non-Soluble Deposit (NSDD) can reduce voltage withstand capability of Fiberglass-Reinforced Plastic (FRP)
Autor:
Masoud Farzaneh, W. A. Chisholm
Publikováno v:
IEEE Electrical Insulation Magazine. 30:14-24
During the last 50 years a significant technical advance, namely in our understanding and control of switching-surge overvoltages, has had some unintended and adverse consequences when designers took full advantage of the possibility of reduced insul
Publikováno v:
Cultivator & Country Gentleman; 3/30/1876, Vol. 41 Issue 1209, p205-205, 1/9p