Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Volker Carrero"'
Autor:
Matthias Honl, Florian Westphal, Volker Carrero, Michael Morlock, Karsten Schwieger, Ekkehard Hille, G. Delling
Publikováno v:
Sarcoma, Vol 7, Iss 3-4, Pp 177-182 (2003)
A case of lytic lesion of the pelvis in a 23-year-old woman is presented. A biopsy led to the diagnosis aneurysmal bone cyst (ABC). Due to the histologically very aggressive growth of the tumor, a low malignant osteosarcoma could not be excluded. In
Externí odkaz:
https://doaj.org/article/83f75f69eea74fc98e2e94c3897a3148
Autor:
Frank Lampe, Christian Gauck, Volker Carrero, S. Dries, K. Schwieger, Markus Quante, M. Honl, Michael M. Morlock, Ekkehard Hille, Oliver Dierk
Publikováno v:
The Journal of Bone and Joint Surgery-American Volume. 85:1470-1478
Robotic-assisted total hip replacement has become a common method of implantation, especially in Europe. It frequently has been postulated that robotic reaming would result in an improved clinical outcome due to the better fit of the prosthesis, but
Autor:
Oliver Dierk, A. Betthäuser, K. Schwieger, Michael M. Morlock, S. Dries, W. W. Höpker, M. Honl, H. Uebeyli, Volker Carrero, Ekkehard Hille, Reemt Rentzsch
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 141:322-327
AIM The selectivity of a water jet (WJ) is already used with clinical advantage in the surgery of liver, brain, kidney and herniated lumbar discs. The aim of the present study was to determine whether a WJ can be used for synovectomy without damaging
Autor:
F Pude, M. Honl, Ekkehard Hille, Sebastian P. M. Dries, Volker Carrero, Andrea Bluhm, Oliver Dierk, Reemt Rentzsch, Hartmut Louis, K. Schwieger, Michael M. Morlock
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 48:275-280
Conventional tools used in prosthetic revision surgery have a limited range of action within the narrow cement mantle. Water jet cutting technology permits tiny and precisely controlled cuts, and may therefore be an alternative method of bone cement
Autor:
M. Honl, Florian Westphal, Günter Delling, Ekkehard Hille, Michael M. Morlock, K. Schwieger, Volker Carrero
Publikováno v:
Sarcoma
Sarcoma, vol. 7, no. 3-4, pp. 177-182, 2003
Sarcoma, Vol 7, Iss 3-4, Pp 177-182 (2003)
Sarcoma, vol. 7, no. 3-4, pp. 177-182, 2003
Sarcoma, Vol 7, Iss 3-4, Pp 177-182 (2003)
A case of lytic lesion of the pelvis in a 23-year-old woman is presented. A biopsy led to the diagnosis aneurysmal bone cyst(ABC). Due to the histologically very aggressive growth of the tumor, a low malignant osteosarcoma could not be excluded.In an
Publikováno v:
The American journal of sports medicine 4 (30): 549-557 (2002 Jul-Aug)
BackgroundSecure fixation is an important factor in the success of anterior cruciate ligament reconstruction.HypothesisThere is no difference in the mechanical behavior of reconstructions from method of fixation or method of testing.Study DesignContr
Autor:
K. Schwieger, M. Honl, Nicholas E. Bishop, Michael M. Morlock, Hartmut Louis, Ekkehard Hille, Volker Carrero, Axel Becker, Reemt Rentzsch
Publikováno v:
Journal of biomedical materials research. Part B, Applied biomaterials. 71(2)
The quality of bone cuts is assessed by the accuracy and biological potency of the cut surfaces. Conventional tools (such as saws and milling machines) can cause thermal damage to bone tissue. Water jet cutting is nonthermal; that is, it does not gen
Autor:
Matthias, Honl, Reemt, Rentzsch, Karsten, Schwieger, Volker, Carrero, Oliver, Dierk, Sebastian, Dries, Hartmut, Louis, Frank, Pude, Nick, Bishop, Ekkehard, Hille, Michael, Morlock
Publikováno v:
Bio-medical materials and engineering. 13(4)
In revision surgeries of endoprostheses, the interface between implant and bone cement or bone must be loosened. Conventional tools have many disadvantages because of their size and limited range. Taking advantage of the selective and athermic cuttin
Autor:
Matthias, Honl, Karsten, Schwieger, Volker, Carrero, Reemt, Rentzsch, Oliver, Dierk, Sebastian, Dries, Frank, Pude, Andrea, Bluhm, Ekkehard, Hille, Hartmut, Louis, Michael, Morlock
Publikováno v:
Biomedizinische Technik. Biomedical engineering. 48(10)
Conventional tools used in prosthetic revision surgery have a limited range of action within the narrow cement mantle. Water jet cutting technology permits tiny and precisely controlled cuts, and may therefore be an alternative method of bone cement