Zobrazeno 1 - 10
of 43
pro vyhledávání: '"Vladimír Tobyáš"'
Publikováno v:
Studia Geophysica et Geodaetica. 43:185-193
The amplitude response of a LCR gravimeter with the SRW-E feedback was determined on a vertical vibrating platform. The ink-pen recorder was connected parallel with the digital voltmeter input to obtain an analog response of the gravimeter to the har
Autor:
Vladimír Tobyáš, Reinhard Mittag
Publikováno v:
Studia Geophysica et Geodaetica. 37:159-167
New calibrating functions for the local magnitude ML based on the maximum ratio of amplitude and period of the Sg - wave, the short-period surface wave and the duration of the whole seismogram and its part starting with the arrival of the Sg -wave re
Autor:
Reinhard Mittag, Vladimír Tobyáš
Publikováno v:
Studia Geophysica et Geodaetica. 36:207-214
The seismic activity of the region is analysed on the basis of the recent microseismic and former macroseismic observations. Only microearthquakes in the narrow magnitude range of 0–1.2 were monitored during 1982–1988. The mean annual frequencies
Autor:
Reinhard Mittag, Vladimír Tobyáš
Publikováno v:
Studia Geophysica et Geodaetica. 35:354-357
The local magnitude ML at the seismological station Pruhonice (PRU) was converted into surface wave magnitude MS using the formula MS=−3.2+1.45 ML and the seismic wave energy was estimated using the relation log E (Joule)=1.2+2.0 ML. It was propose
Autor:
J. Janský, Vladimír Tobyáš
Publikováno v:
Studia Geophysica et Geodaetica. 25:99-103
Drawing on the results of new measurements of the mechanical parameters of the SVK seismometer No. 5055, the level of magnification of the vertical seismograph used in the past, has been corrected. The amplitudes of the seismic waves from earthquakes
Publikováno v:
Studia Geophysica et Geodaetica. 29:68-74
The effectiveness of recording seismic phenomena in the Krusne hory (Mts.) region in NW Bohemia by selected stations in the CSR, GDR and Poland has been estimated. Magnitude isolines of the weakest earthquakes, which can be localized and detected wit
Autor:
Vladimír Tobyáš, J. Buben
Publikováno v:
Studia Geophysica et Geodaetica. 18:140-148
Polynomials for computing a) the coupling coefficients for a given magnification and the parameters of the seismometer and galvanometer (Tab. 3), b) partial constants as a function of the coupling coefficient (Tab. 2) are derived for standard AI–AI
Publikováno v:
Studia Geophysica et Geodaetica. 22:336-347
Relations for computing the minimum amplitudes of ground vibrations which generate oscillations of the gravity meter reading beam at the limit of the resolution of the optical system, have been derived. The minimum amplitudes in the ground displaceme
Autor:
Vladimír Tobyáš, J. Buben
Publikováno v:
Studia Geophysica et Geodaetica. 21:19-26
The maximum changes of magnification were determined for electrodynamic seismographs with standard characteristics and for some experimental long-period seismographs, the constants of which are given in Tab. 1, when the period of the seismometer or g
Publikováno v:
Studia Geophysica et Geodaetica. 30:217-223
Tests on the vertical vibrating table in the frequency range of70–110 Hz indicate that quartz gravity meters are10–100 times more sensitive at some frequencies than under low-frequency excitation. At high frequencies, the reading beam is at rest