Nuclear Engineering and Technology, Vol 48, Iss 2, Pp 419-433 (2016)
One of the important severe accident management measures in the Light Water Reactors is water injection to the reactor core. The related phenomena are investigated by performing experiments and computer simulations. One of the most widely known is th
Externí odkaz:
https://doaj.org/article/10235b8053c34125a3d13ed2c218b182
Publikováno v:
Science and Technology of Nuclear Installations, Vol 2008 (2008)
Eight main circulation pumps (MCPs) are employed for the cooling of water forced circulation through the RBMK-1500 reactor at the Ignalina nuclear power plant (NPP). These pumps are joined into groups of four pumps each (three for normal operation an
Externí odkaz:
https://doaj.org/article/2e40fb695df84cfc8a9ccac2719dc935
Autor:
Chatelard, Patrick, Garo Azarian, Alexandre Ezzidi, Prasanna Majumdar, Hemant Lele, Joan Fontanet, Luis Enrique Herranz, Virginie Lombard, Andreas Schumm, Kalchev, Boris, Giacomino Bandini, Felice de Rosa, Siegfried Arndt, Holger Nowack, Marin Constantin, Andrei Rizoiu, Grudev, Pavlin, Laure Carénini, Karine Chevalier Jabet, Kljenak, Ivo, Weimin, Ma, Heinrich Muscher, Juri Stuckert, Algirdas Kaliatka, Virginijus Vileiniskis, Gabor Lajtha, Pal Kostka, Thimo Brähler, Tobias Risken, Ivan Ivanov, Petar Kaleychev, Kubisova, Lubica, Miroslav Kotouc, Bohumir Kujal, Paci, Sandro, Buck, Michael, Nieminen, Anna, Albert Bujan, Juraj Jancovic
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=od______3728::4dfff86cbf4bae36d50fda0870b599a2
http://hdl.handle.net/11568/751353
http://hdl.handle.net/11568/751353
Publikováno v:
Science and Technology of Nuclear Installations, Vol 2014 (2014)
To prevent total meltdown of the uncovered and overheated core, the reflooding with water is a necessary accident management measure. Because these actions lead to the generation of hydrogen, which can cause further problems, the related phenomena ar
Externí odkaz:
https://doaj.org/article/ca332a7e6b0a47879d495e1f4716c938
Publikováno v:
Science and Technology of Nuclear Installations, Vol 2013 (2013)
The safe storage of spent fuel assemblies in the spent fuel pools is very important. These facilities are not covered by leaktight containment; thus, the consequences of overheating and melting of fuel in the spent fuel pools can be very severe. On t