Publikováno v:
Challenging Glass Conference Proceedings, Vol 9 (2024)
The control of glare in office environments is often retrospectively improvised using shading devices, typically internal blinds. This also involves blocking the view, with an unwarranted artificial lighting load during broad daylight. Today’s glaz
Externí odkaz:
https://doaj.org/article/4b1ae318ecf14595b935969829a022c0
Publikováno v:
Buildings, Vol 12, Iss 8, p 1239 (2022)
Sound insulation design for structural glazed façade is an important task in environmental noise control, as increased continuously repeated noise is a significant factor impacting on people’s well-being and is associated with a negative impact on
Externí odkaz:
https://doaj.org/article/98d8b83f8bd14073b5fa3d79e8cfd5bf
Publikováno v:
Proceedings, Vol 51, Iss 1, p 16 (2020)
This paper is the research output of the laboratory ageing of external thermal insulation composite systems (ETICS). This was carried out in order to study the changes in properties of systems consisting of combustible and non-combustible thermal ins
Externí odkaz:
https://doaj.org/article/97fe6ccc24b34497bc040063a843db5f
Publikováno v:
Buildings; Volume 12; Issue 8; Pages: 1239
Sound insulation design for structural glazed façade is an important task in environmental noise control, as increased continuously repeated noise is a significant factor impacting on people’s well-being and is associated with a negative impact on
Publikováno v:
Sustainability
Volume 13
Issue 16
Sustainability, Vol 13, Iss 9220, p 9220 (2021)
Volume 13
Issue 16
Sustainability, Vol 13, Iss 9220, p 9220 (2021)
The article presents the results of a set of hygrothermal experiments of an external wall insulated with an ETICS. As an add-on to previous studies, thermal insulation in the form of polystyrene with an additional horizontal strip of mineral wool was
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::946864d549fac0473908ff34002eaffd
https://www.um.edu.mt/library/oar/handle/123456789/82219
https://www.um.edu.mt/library/oar/handle/123456789/82219
Publikováno v:
Energy and Buildings. 133:658-669
The influence of courtyard height on the cross-ventilation of a room abating a courtyard building is addressed in this work. While the cross-ventilation performance of isolated buildings has been thoroughly documented in the literature, the phenomeno
Publikováno v:
Journal of Building Engineering. 32:101682
This paper investigates the mechanical resistance of ETICS, with different types of thin-layer rendering, by means of hard body and point load impacts on such surfaces. Core materials, made of different thicknesses of EPS (expanded polystyrene) were
Autor:
S De Marco, Vincent Buhagiar
Publikováno v:
IOP Conference Series: Earth and Environmental Science. 329:012037
The present local built environment has a common thermal comfort problem namely that most dwellings have a great reliance on electricity for environmental control indoors. The main objective of this research work was to offer a practical and cost-eff
Publikováno v:
Sustainable Buildings, Vol 3, p 4 (2018)
The present case study sets out to investigate the potential and limitations of passive building design in a typical Mediterranean climate. The Maltese Islands were taken as the case study location. Assuming a fully detached, cuboid-shaped, generic m