Zobrazeno 1 - 10
of 18
pro vyhledávání: '"Vincent, Garitey"'
Autor:
F. Mouret, J. Ramos-Clamote, Mourad Boufi, J.M. Chevalier, Vincent Garitey, A. Millon, Z. Hakam, Y.S. Alimi
Publikováno v:
European Journal of Vascular and Endovascular Surgery. 35:730-736
Objectives The aim of this study was to assess the feasibility and efficacy of a new laparoscopic vascular suturing device. Methods Animal study : six pigs underwent surgery using a retroperitoneal laparoscopic approach. Aorto-prosthetic side-to-end
Publikováno v:
Journal of Biomechanics. 37:1749-1755
Aims: The flow dynamics in the atrium is poorly described. The reasons are principally due to the complicated geometry of the cavity and its contractility. The present in vitro study focuses on the description of the flow in the left atrium in normal
Publikováno v:
Cardiovascular Engineering. 2:139-148
Valve trials are often run under simulated conditions encountered in healthy young men. However, heart valve implantation is often associated with other pathologies. The study was focused on the impact of the variation of the heart rate on prosthesis
Autor:
Anthony H. Gershlick, Vincent Garitey, Amerjeet Banning, Justyna Janus, Michael E. Kelly, Karim Mouniemne, Julian Gunn
Publikováno v:
Journal of the American College of Cardiology. 69:1065
Background: For coronary bifurcation lesions, provisional T-stent is the default strategy since two-stent strategies demonstrate worse outcomes in meta-analyses. An optimal side-branch stent design may prove otherwise. We have developed a totally nov
Autor:
Jean Fuseri, Vincent Garitey, Catherine Masson, Paul Barragan, Pierre O. Roquebert, Régis Rieu, Marc Silvestri
Publikováno v:
Catheterization and Cardiovascular Interventions. 46:380-391
High radial force has become an essential feature of new coronary stents. These stents are expected to exhibit sufficient radial force and minimum radial recoil when deployed in atheromatous lesions of various morphologies. The aim of this study was
Publikováno v:
Journal of Clinical Engineering. 23:409-415
Publikováno v:
Journal of the American College of Cardiology. 60(17)
Significant longitudinal compression has been clinically observed in cases where drug-eluting coronary stents were crossed by other interventional devices. Our objective was to characterize stent longitudinal resistance under simulated clinical worst
Publikováno v:
The International Journal of Artificial Organs. 15:295-300
Using a cardiovascular simulator to duplicate in vitro the flow conditions through valves in aortic position, bidimensional velocity maps very near the valve are reconstructed, from an ultrasonic 8 Mhz doppler system, in an elastic model of the ascen
Publikováno v:
Surgical technology international. 14
In addition to conventional and endovascular techniques, laparoscopic surgery is becoming a third way to treat patients with aortoiliac occlusive or aneurysmal diseases. Several different laparoscopic techniques are available, but most authors are st
Publikováno v:
European Journal of Vascular and Endovascular Surgery
European Journal of Vascular and Endovascular Surgery, 2004, 28, n° 3, pp.281-286
European Journal of Vascular and Endovascular Surgery, Elsevier, 2004, 28, n° 3, pp.281-286
European Journal of Vascular and Endovascular Surgery, 2004, 28, n° 3, pp.281-286
European Journal of Vascular and Endovascular Surgery, Elsevier, 2004, 28, n° 3, pp.281-286
Objectives. To evaluate ligation of aortoiliac arteries with laparoscopic staplers in order to develop specifically designed staplers. Methods. Cadaveric study. Seven human cadaver aortas were stapled using EndoGIA60® staplers. Efficiency was evalua
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a090046556bb6e15bc13911bd4da1b1c
https://hal.science/hal-00014880
https://hal.science/hal-00014880