Mahdi Bayat, Steve Majerus, Vida Pashaei, George Enwia, Soumyajit Mandal, Parisa Dehghanzadeh
Publikováno v:
IEEE Transactions on Biomedical Circuits and Systems. 14:305-318
The paper presents the design and validation of body-conformal active ultrasound patches with integrated imaging and modulation modalities for image-guided neural therapy. A mechanically-flexible linear 64-element array of piezoelectric transducers w
Autor:
Umut A. Gurkan, Vida Pashaei, Chen Yuan Chung, Myeongseop Kim, Muhammad Noman Hasan, Abhishek Kakkar, A. N. Radwan, Erdem Kucukal, Debnath Maji
Publikováno v:
TECHNOLOGY. :57-83
Neural activity that occur during motor movement, speech, thought, and various other events can be observed in the form of brainwaves composed of synchronized electrical pulses emitted from adjoining communicative neurons. Observations of these brain
Publikováno v:
2020 IEEE SENSORS.
This paper presents the design and validation of a novel magnetic system for ophthalmic realignment in patients with damaged or lost extra-ocular muscles. The system utilizes two sets of Neodymium-Iron-Boron (NdFeB) magnets to replace the damaged mus
Autor:
Zenghui Wang, Guo Jun Ye, Jaesung Lee, Xianhui Chen, Wei Du, Hao Jia, Arnob Islam, Vida Pashaei, Philip X.-L. Feng
Publikováno v:
ACS Applied Materials & Interfaces. 10:25629-25637
Strong in-plane anisotropy of atomic layer and thin-film black phosphorus (P) offers new device perspectives and stimulates increasing interest and explorations, where precisely determining the black P crystal orientation and anisotropic axes is a ne
Publikováno v:
2019 IEEE National Aerospace and Electronics Conference (NAECON).
Many emerging ultrasound-based imaging modalities depend on operation in the low signal-to-noise ratio (SNR) regime. This paper describes a compact and wearable autonomous ultrasound imaging system for such applications. The system uses a 64-element
Autor:
Guru Subramanyam, Sanjeevi Sirisha Karri, Parisa Dehghanzadeh, Priyanka Aggarwal, Vida Pashaei, Soumyajit Mandal
Publikováno v:
2019 IEEE National Aerospace and Electronics Conference (NAECON).
This paper focuses on techniques to acquire good-quality ultrasound images that can be analyzed to provide an appropriate therapeutic regimen. We consider the problem of image-guided neuromodulation of the vagus nerve (VN). A robust template-matching
Autor:
Vida Pashaei, David C. Gross
Publikováno v:
Communications in Computer and Information Science ISBN: 9783030235246
HCI (35)
HCI (35)
Although Situational Awareness (SA) has been an active area of research for decades, the integration of SA system frameworks specifically within the healthcare industry is a fairly new topic of interest. Recent, rapid advances in technology, especial
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::8dc5af0b03d3c09857b374ba2e2f3a70
https://doi.org/10.1007/978-3-030-23525-3_67
https://doi.org/10.1007/978-3-030-23525-3_67
Publikováno v:
BioCAS
A complete low-cost open-source portable ultrasound test bench will be demonstrated for a variety of biomedical imaging applications. The test bench is a programmable 64-channel system with a modular design that can be easily updated with improved ha
Publikováno v:
BioCAS
The paper discusses the design and validation of a novel wearable conformal ultrasound array with integrated imaging and modulation capabilities. A custom 64-element linear PZT array with 5 MHz resonance frequency was used for imaging. An 8-element l
Autor:
Philip X.-L. Feng, Charles N. Arutt, Christian A. Zorman, Michael W. McCurdy, Michael L. Alles, Hao Jia, Hailong Chen, Vida Pashaei, Robert A. Reed, RonaldD. Schrimpf, Wenjun Liao
Publikováno v:
2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS).
We report on measuring radiation effects of energetic oxygen ions on silicon carbide (SiC) diaphragm resonators. Micromachined SiC diaphragms (1 mm × 1 mm × 2μm) vibrating at ∼200–800 kHz on multimode resonances are exposed to 14.3 MeV oxygen