Zobrazeno 1 - 10
of 41
pro vyhledávání: '"Victor Lien"'
Publikováno v:
IEEE Journal of Selected Topics in Quantum Electronics. 11:827-834
We demonstrate a new detection scheme for a microfabricated flow cytometer. The fluidic-photonic integrated circuits (FPICs) that perform flow cytometric detection possess new functionality, such as on-chip excitation, time-of-flight measurement, and
Publikováno v:
IEEE Photonics Technology Letters. 19:441-443
Scattering-based on-chip excitation and detection on the arrayed-waveguide platform has been developed and implemented. Detected signals were processed with the proposed multiplication-based cross-correlation algorithm. The algorithm is capable of no
Publikováno v:
Lab on a chip. 13(9)
We have demonstrated a microfluidic device that can not only achieve three-dimensional flow focusing but also confine particles to the center stream along the channel. The device has a sample channel of smaller height and two sheath flow channels of
Publikováno v:
IEEE Photonics Technology Letters. 16:1525-1527
We present a novel technology to monolithically integrate buried heterostructure waveguides with microfluidic channels in a prealigned manner. The fabrication process produced sealed microfluidic channels, low-loss waveguides, and excellent waveguide
Publikováno v:
Applied Physics Letters. 83:5563-5565
We demonstrate a technique to fabricate spherical micromirrors with a programmable focal length by microfluidic capillary. Micromirrors with focal lengths of 13 μm, 19 μm, 28 μm, 50 μm, and a flat mirror were fabricated and characterized. These m
Publikováno v:
IEEE Photonics Technology Letters. 15:712-714
Summary form only given. We demonstrated that, by using the elastomer PDMS (polydimethylsiloxane), one can form gratings of any desired chirp characteristics by simply designing the geometric profile of the material. Using two kinds of linearly taper
Publikováno v:
2006 IEEE LEOS Annual Meeting Conference Proceedings.
Cylindrical fluid-filled lenses microfabricated in polydimethylsiloxane (PDMS) polymer are incorporated into a microfluidic flow cytometer to localize excitation in the channel and enable multi-parameter in-plane scatter detection.
Publikováno v:
2006 Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference.
Focusing is demonstrated in fluid-filled microfabricated 2D lenses formed by an optical polymer. Such lenses can be integrated into fluidic photonic devices performing flow cytometry for increased detection efficiency and device functionality.
Publikováno v:
2006 Conference on Lasers and Electro-Optics and 2006 Quantum Electronics and Laser Science Conference.
An acousto-optical microfluidic flow cytometer featuring femtoliter fluid-displacement was demonstrated with cellular sorting efficiencies at upwards of 99% at 5 kHz frequency actuation. Simulation and validation was performed using Reynolds stress m
Publikováno v:
(CLEO). Conference on Lasers and Electro-Optics, 2005..
We present a fluidic photonic integrated circuit (FPIC) performing the detection function for flow cytometry. An array waveguide design was chosen to achieve superb sensitivity and the time-of-flight measurement for each particle flowing by.