Zobrazeno 1 - 10
of 15
pro vyhledávání: '"Victor Haughton"'
Autor:
Stephanie Sincomb, Francisco Moral-Pulido, Obed Campos, Carlos Martinez-Bazan, Victor Haughton, Antonio Sanchez
Background: The cerebrospinal fluid filling the ventricles of the brain moves with a cyclic velocity driven by the transmantle pressure, or instantaneous pressure difference between the lateral ventricles and the cerebral subarachnoid space. This dyn
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::306b10af1cecc3aa04d0febc7ceb8f0c
https://doi.org/10.21203/rs.3.rs-2757861/v1
https://doi.org/10.21203/rs.3.rs-2757861/v1
Autor:
Hans Petter Langtangen, Martin Sandve Alnæs, Karen H. Støverud, Kent-Andre Mardal, Victor Haughton
Publikováno v:
Computer Methods in Biomechanics and Biomedical Engineering. 19:686-698
Syringomyelia, fluid-filled cavities within the spinal cord, occurs frequently in association with a Chiari I malformation and produces some of its most severe neurological symptoms. The exact mechanism causing syringomyelia remains unknown. Since sy
Publikováno v:
Handbook of clinical neurology. 135
This chapter uses magnetic resonance imaging phase-contrast cerebrospinal fluid (CSF) flow measurements to predict which clinical normal-pressure hydrocephalus (NPH) patients will respond to shunting as well as which patients with Chiari I are likely
Publikováno v:
AJNR Am J Neuroradiol
BACKGROUND AND PURPOSE: How CSF flow varies with the anatomy of the subarachnoid space has not been sufficiently well studied. The goal of this study was to develop an idealized 3D computational model of the subarachnoid space and then to use this mo
Autor:
Tianliang, Gu, Frank R, Korosec, Walter F, Block, Sean B, Fain, Quill, Turk, Darren, Lum, Yong, Zhou, Thomas M, Grist, Victor, Haughton, Charles A, Mistretta
Publikováno v:
AJNR Am J Neuroradiol
BACKGROUND AND PURPOSE: Three-dimensional phase-contrast (3DPC) is limited by long imaging times, limited coverage, flow artifacts, and the need to perform multiple additional 2D examinations (2DPC) to measure flow. A highly undersampled 3D radial ac
Autor:
Victor Haughton
Publikováno v:
Spine. 24:53
Autor:
Victor Haughton
Publikováno v:
Spine (03622436); Dec2004, Vol. 29 Issue 23, p2751-2756, 6p
Autor:
Mariana Lazar, David M. Weinstein, Jay S. Tsuruda, Khader M. Hasan, Konstantinos Arfanakis, M. Elizabeth Meyerand, Benham Badie, Howard A. Rowley, Victor Haughton, Aaron Field
Publikováno v:
Human Brain Mapping; Apr2003, Vol. 18 Issue 4, p306, 16p
Peripheral venous scintillation angiocardiography in determination of left ventricular volume in man
Autor:
Victor Haughton, William R. Vetter, John M. Vogel, Dale A. Bergeron, Kenneth H. Hyatt, Robert W. Sullivan
Publikováno v:
The American Journal of Cardiology. 28:563-567
Left ventricular end-diastolic volume was determined by cardiac visualization after peripheral venous injection of a gamma-emitting isotope in 10 patients with organic heart disease. The left ventricular end-diastolic volume measured by the isotope m
Autor:
Victor Haughton
Publikováno v:
Diseases of the Chest. 53:617-628
SUMMARY Dynamic pulmonary compliance was measured during normal and deep breathing in patients undergoing cardiac surgery. Prior to surgery, different groups of patients had varying responses to deep breathing. Patients with pulmonic stenosis showed