Autor:
Vibin Shalom Simon, Himanshu Modi, Krishna Bhavana Sivaraju, Pratik Bansode, Satyam Saini, Pardeep Shahi, Saket Karajgikar, Veerendra Mulay, Dereje Agonafer
Publikováno v:
ASME 2022 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems.
Due to increased use of high-performance computing in datacenters to cater to huge workloads, old low-performance compute servers must be replaced endlessly with high-performance compute servers. Traditional air-cooling systems are insufficient to pr
Publikováno v:
ASME 2022 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems.
In this paper, a standard air-cooled high-density storage system is reengineered to demonstrate the use of single-phase immersion cooling. The storage system consists primarily of seventy-two hard drives, two single socket nodes, two SAS expander car
Comparative Study of Single-Phase Immersion Cooled Two Socket Server in Tank and Sled Configurations
Autor:
Krishna Bhavana Sivaraju, Pratik Bansode, Gautam Gupta, Jacob Lamotte-Dawaghreh, Satyam Saini, Vibin Simon, Joseph Herring, Saket Karajgikar, Veerendra Mulay, Dereje Agonafer
Publikováno v:
ASME 2022 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems.
Submerging a cluster of servers inside a large tank is the customary way of employing single-phase immersion cooling. But this approach requires a complete renovation of existing air-cooled infrastructure. A practical approach to convert an air-coole
Autor:
Dereje Agonafer, Pavan Rajmane, Ashwin Siddarth, Jimil M. Shah, Richard Eiland, Veerendra Mulay
Publikováno v:
Journal of Electronic Packaging. 141
The improved efficiency of mineral oil may offer simplicity in facility design compared to traditional air cooling and provide a means for cost savings. Despite its improved cooling efficiency and cost savings, a mineral oil immersion cooling techniq
Publikováno v:
Journal of Electronic Packaging. 139
Fan efficiency is known to increase with size. In part I of this study, savings in server fan power on the order of 50% were reported by replacing server-enclosed 60 mm fans with a rear-mounted wall of larger fans (80 mm or 120 mm in size). A methodo
Publikováno v:
Journal of Electronic Packaging. 139
In general, smaller fans operate at lower efficiencies than larger fans of proportional linear dimensions. In this work, the applicability of replacing smaller, 60 mm baseline fans from within the chassis of web servers with an array of larger, geome
Autor:
Dereje Agonafer, Veerendra Mulay, Mathan Kumar, Chinmay Kshirsagar, Jacob Na, Patrick McGinn, Fernandes John Edward, Manasa Sahini, Michael Soares
Publikováno v:
2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM).
In the wake of ever-growing demand for power and energy across US and worldwide, development of energy efficient solutions has become very important. Considering data center applications, cooling power consumption constitutes significant part of the
Autor:
Veerendra Mulay
Publikováno v:
2017 33rd Thermal Measurement, Modeling & Management Symposium (SEMI-THERM).
Publikováno v:
2015 31st Thermal Measurement, Modeling & Management Symposium (SEMI-THERM).
Data center cooling strategies have changed overtime due to increases in power densities and server cooling power requirement. Traditionally, most data centers adopt air cooling where the computer room air conditioner (CRAC) units pump volumes of chi
Publikováno v:
2015 31st Thermal Measurement, Modeling & Management Symposium (SEMI-THERM).
A critical requirement in implementation of air cooling for rack mount servers is management of airflow to ensure that all components, especially critical devices such as CPUs, receive adequate flow as per requirement. In addition, component location