Zobrazeno 1 - 8
of 8
pro vyhledávání: '"Varanya Khejonnit"'
Publikováno v:
Siriraj Medical Journal, Vol 62, Iss 4 (2020)
Objective: To compare the performance of the Urised, an image-based automated urine sediment analyzer, against the manual method in urine sediment analysis. Methods: The study was carried out in the Department of Clinical Pathology, Faculty of Med
Externí odkaz:
https://doaj.org/article/bef8fc90f39747bf82fe2c8a4f5b9334
Publikováno v:
Journal of Orthopaedic Research. 35:2545-2550
Centrifugation of aspirated synovial fluid before leukocytes esterase (LE) testing for diagnosing periprosthetic joint infection (PJI) may make blood tinged specimens interpretable. We aimed to establish the proper sampling depth of centrifuged speci
Autor:
Kanit Reesukumal, Chanutchaya Pattanavin, Preechaya Wongkrajang, Varanya Khejonnit, Suriya Meepanya, Busadee Pratumvinit, Bongkot Wesarachkitti
Publikováno v:
Laboratory Medicine. 47:124-133
Objective: To evaluate and compare the performances of the automated urinalysis devices UX-2000 and Cobas 6500. Method: A total of 258 urine specimens were collected from the routine specimen workload. We analyzed all specimens on both automated inst
Autor:
Preechaya Wongkrajang, Chonticha Bucha, Chanutchaya Pattanavin, Sathima Laiwejpithaya, Suriya Meepanya, Kanit Reesukumal, Varanya Khejonnit, Achara Chuntarut
Background Fully automated urine analyzers now play an important role in routine urinalysis in most laboratories. The recently introduced UriSed 3 has a new automated digital imaging urine sediment analyzer with a phase contrast feature. The aim of t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::93d5d79caacdb89555c50f243b4cba00
https://europepmc.org/articles/PMC6817101/
https://europepmc.org/articles/PMC6817101/
Autor:
Pakpoom, Ruangsomboon, Sriprapa, Chinprasertsuk, Varanya, Khejonnit, Keerati, Chareancholvanich
Publikováno v:
Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 35(11)
Centrifugation of aspirated synovial fluid before leukocytes esterase (LE) testing for diagnosing periprosthetic joint infection (PJI) may make blood tinged specimens interpretable. We aimed to establish the proper sampling depth of centrifuged speci
Autor:
Preechaya Wongkrajang, Suriya Meepanya, Busadee Pratumvinit, Varanya Khejonnit, Kanit Reesukumal, Chanutchaya Pattanavin
Publikováno v:
Clinica chimica acta; international journal of clinical chemistry. 439
Background The Sysmex UX-2000 is a new, fully automated integrated urine analyzer. This device analyzes all physical and chemical characteristics of urine and sediments in urine on single platform. Because sediment analysis by fluorescent flow cytome
Autor:
Preechaya Wongkrajang, Cherdsak Klinbua, Weerapol Dangneawnoi, Varanya Khejonnit, Busadee Pratumvinit, Kanit Reesukumal
Publikováno v:
Clinica chimica acta; international journal of clinical chemistry. 426
Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples.From 130 urine samples obtained vi
Autor:
Bongkot Wesarachkitti, Varanya Khejonnit, Busadee Pratumvinit, Kanit Reesukumal, Suriya Meepanya, Chanutchaya Pattanavin, Preechaya Wongkrajang
Publikováno v:
Laboratory Medicine; May2016, Vol. 47 Issue 2, p124-133, 10p