Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Vanessa I. Vera"'
Publikováno v:
Clinical Ophthalmology. 14:2361-2371
The XEN Gel Stent (Allergan Inc., an Abbvie company) is an implant that lowers intraocular pressure by creating a filtration pathway from the anterior chamber to the subconjunctival space, using the same pathway as trabeculectomy. While the primary m
Publikováno v:
Clinical Ophthalmology. 13:685-694
Surgical management of glaucoma offers a means of effective disease control. A gel stent that facilitates drainage to the subconjunctival space offers intraocular pressure (IOP) reduction similar to traditional glaucoma filtering surgeries in a less
Autor:
Andrew Shirlaw, Leon Au, Simon Ruben, Vanessa I. Vera, Jorge Vila-Arteaga, Ingeborg Stalmans, Herbert A. Reitsamer, Mini Balaram, Miguel A. Teus, Markus Lenzhofer, Zhanying Bai
Publikováno v:
Acta ophthalmologica. 100(1)
PURPOSE: To assess the 3-year effectiveness and safety of the XEN gel stent implanted ab interno in open-angle glaucoma (OAG). METHODS: This study was a multicentre, retrospective chart review of consecutive patients with OAG who underwent ab-interno
Autor:
E. Ansari, Helmut Höh, Vanessa I. Vera, Tarek Shaarawy, Clemens Vass, Fritz H. Hengerer, Chelvin C A Sng, Leon Au, Kin Sheng Lim, M. Nagar, Keith Barton, G. Marchini, Marco Nardi, Antonio Maria Fea, H. B. Dick, Ingeborg Stalmans, Marek Rękas, Georg Mossböck, Herbert A. Reitsamer, Cosme Lavin-Dapena, Miguel A. Teus, Markus Lenzhofer, L. Cadarso, I. Masood
Publikováno v:
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 257(5)
PURPOSE: To evaluate the effectiveness of an ab interno subconjunctival gelatin implant as primary surgical intervention in reducing intraocular pressure (IOP) and IOP-lowering medication count in medically uncontrolled moderate primary open-angle gl
Publikováno v:
Ophthalmology. 125:e36
Publikováno v:
US Ophthalmic Review. 11:38
The surgical management of glaucoma offers the potential to lower intraocular pressure (IOP) independent of patients’ compliance with their medication regimen. Procedures such as trabeculectomy and tube shunt placement often yield large magnitudes
Autor:
Christopher Horvath, Vanessa I. Vera
Publikováno v:
Surgical Innovations in Glaucoma ISBN: 9781461483472
XEN Gel Stent is the solution developed by AqueSys, Inc. by merging together the best of both worlds: a long time proven outflow mechanism of action at the subconjunctival space with a minimally invasive approach creating Minimally Invasive Maximum E
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::326f64f2278308ac07ee28d3462d6702
https://doi.org/10.1007/978-1-4614-8348-9_17
https://doi.org/10.1007/978-1-4614-8348-9_17
Publikováno v:
American journal of ophthalmology. 157(5)
Purpose To determine if the location of neodymium:yttrium–aluminum–garnet laser peripheral iridotomy (LPI) is related to the occurrence of postoperative visual dysphotopsia. Design Randomized, prospective, single-masked, paired-eye comparative cl
Autor:
Vera, Vanessa I., Horvath, Christopher
Publikováno v:
Surgical Innovations in Glaucoma; 2014, p189-198, 10p
Publikováno v:
Surgical Innovations in Glaucoma; 2014, pi-xi, 11p