Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Van Hoai Viet Le"'
Autor:
Real Lebeau MD, Karim Serri MD, Maria Di Lorenzo MD, Claude Sauvé MD, Van Hoai Viet Le MD, Malak El-Rayes MD, Maude Pagé MD, Chimène Zaïani MD, Jérôme Garot MD, Frédéric Poulin MD MSc
Publikováno v:
Echo Research and Practice, Vol 5, Iss 2, Pp 63-69 (2018)
Background: Simpson biplane method and 3D by transthoracic echocardiography (TTE), radionuclide angiography (RNA) and cardiac magnetic resonance imaging (CMR) are the most accepted techniques for left ventricular ejection fraction (LVEF) assessment.
Externí odkaz:
https://doaj.org/article/da971f5ce468460caa6d69f434e3cfbd
Autor:
Claude Sauvé, Réal Lebeau, Maude Pagé, Van Hoai Viet Le, Vicky Soulieres, Karim Serri, Maria Di Lorenzo, Frédéric Poulin, Jérôme Garot, Chimène Zaïani, Malak El-Rayes
Publikováno v:
Echo Research and Practice, Vol 5, Iss 2, Pp 63-69 (2018)
Echo Research and Practice
Echo Research and Practice
Background: Simpson biplane method and 3D by transthoracic echocardiography (TTE), radionuclide angiography (RNA) and cardiac magnetic resonance imaging (CMR) are the most accepted techniques for left ventricular ejection fraction (LVEF) assessment.
Autor:
Lauren Basmadjian, Ismail El-Hamamsy, Nancy Poirier, Pierre-Emmanuel Noly, Van Hoai Viet Le, Ismail Bouhout
Publikováno v:
Canadian Journal of Cardiology. 32:110-116
Background The clinical presentation, echocardiographic features, and patterns of aortic dilatation in unicuspid aortic valves (UAVs) are not well defined. Methods From 2011 to 2015, all data from adult patients with confirmed UAVs (n = 42) who under
Autor:
Van Hoai Viet Le, Philippe Romeo, Frédéric Poulin, Philippe Généreux, Michel Doucet, Yoan Lamarche
Publikováno v:
The Canadian journal of cardiology. 32(2)
We report on a man with bioprosthetic mitral valve perforation who presented late after transcatheter aortic valve replacement with a balloon-expandable transcatheter heart valve (THV). The protrusion of the commissural strut of the bioprosthetic mit
Publikováno v:
European heart journal. Cardiovascular Imaging. 15(11)
An 83-year-old woman with severe aortic stenosis underwent transcatheter aortic valve replacement (TAVR) using a 29-mm (annulus = 543 mm2) Edwards Sapien XT prosthesis (Edwards Lifesciences, Irvine, CA, USA) ( Panel A ). Following the uneventful depl
Autor:
Melanie Gallant, Frédéric Poulin, Ismail El-Hamamsy, Philippe Demers, Pierre Pagé, Karim Serri, Donald A. Palisaitis, Florent Chevalier, Yanick Beaulieu, Hugues Jeanmart, Van Hoai Viet Le, Anik Daoust, Christophe Heylbroeck, Yoan Lamarche, Philippe Généreux, Erick Schampaert
Publikováno v:
The Canadian journal of cardiology. 30(12)
Background After the approval of transcatheter aortic valve replacement (TAVR) for high-risk or inoperable patients with severe aortic stenosis (AS), many low- and moderate-volume TAVR programs were initiated. Contemporary outcomes from these newly i
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.