Zobrazeno 1 - 10
of 50
pro vyhledávání: '"V.V. Buniatyan"'
Publikováno v:
Armenian Journal of Physics. :117-127
Trapping/detrapping characteristics of thin film metal-ferroelectric-metal (m-f-m, Pt-BaxSr1-xTiO3-Pt) structure is considered assuming that the ferroelectric is in paraelectric phase and high concentration of oxygen vacancies (OV) in the interfacial
Publikováno v:
Advanced Materials & Technologies. :058-066
In Part 2 of the paper, based on the results and assumptions pointed in Part 1, analytical expressions were derived for Schottky barrier thermal/field assisted and Poole-Frenkel emission currents. The computer modeling theoretical dependencies of the
Autor:
V.V. Buniatyan, H.R. Dastoyan
Publikováno v:
Advanced Materials & Technologies. :008-017
Publikováno v:
Sensors, Vol 21, Iss 6161, p 6161 (2021)
Sensors; Volume 21; Issue 18; Pages: 6161
Sensors 21(18), 6161-(2021). doi:10.3390/s21186161
Sensors (Basel, Switzerland)
Sensors; Volume 21; Issue 18; Pages: 6161
Sensors 21(18), 6161-(2021). doi:10.3390/s21186161
Sensors (Basel, Switzerland)
The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip
Publikováno v:
Advanced Materials & Technologies. :035-044
Autor:
Tatsuo Yoshinobu, Michael J. Schöning, Carl Frederik Werner, V.V. Buniatyan, Arshak Poghossian, K. Miamoto, Torsten Wagner
Publikováno v:
Sensors and Actuators B: Chemical. 244:1071-1079
The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection
Autor:
Gohar Tsakanova, L. R. Aloyan, Arsham Yeremyan, S. Sh. Tatikyan, M.V. Derdzyan, Gayane Amatuni, Rouben Aroutiounian, V.V. Harutiunyan, Norayr Martirosyan, Hakob Davtyan, Ashot Vardanyan, Vahagn Vardanyan, N.E. Grigoryan, V.V. Buniatyan, Bagrat Grigoryan, V. Tsakanov, Vahan Petrosyan, Vahe Sahakyan, S.G. Haroutyunian, Ashot Petrosyan, Aram A. Sahakyan, Laura Hakobyan, Avetis Simonyan, E. Tsovyan, Hrant N. Yeritsyan, Yeva B. Dalyan, Nelly Babayan, V.Sh. Avagyan, Gevorg Zanyan, L.G. Aslanyan, G.S. Melikyan, A.A. Sargsyan, K.L. Hovhannesyan, Vitali Khachatryan
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
The AREAL laser-driven RF gun provides 2–5 MeV energy ultrashort electron pulses for experimental study in life and materials sciences. We report the first experimental results of the AREAL beam application in the study of molecular-genetic effects
Autor:
V.V. Buniatyan, Steffen Reisert, Matthias Bäcker, Friederike Kramer, Vardges K. Begoyan, Michael J. Schöning, Arshak Poghossian, Christina Huck
Publikováno v:
physica status solidi (a). 212:1254-1259
High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes c
Autor:
Patrick Wagner, Willi Zander, Matthias Bäcker, Christina Huck, Arshak Poghossian, V.K. Begoyan, S. Chaudhuri, Michael J. Schöning, Jürgen Schubert, V.V. Buniatyan
Publikováno v:
Sensors and Actuators B: Chemical. 198:102-109
A miniaturized capacitively coupled contactless conductivity detection (C 4 D) sensor based on high-k perovskite oxide of barium strontium titanate (BST) has been implemented for the first time. The BST films (∼120 nm thick) of Ba 0.25 Sr 0.75 TiO
Autor:
Arshak Poghossian, Willi Zander, Matthias Bäcker, Sebastian Schusser, Juergen Schubert, V.V. Buniatyan, Michael J. Schöning, Norayr Martirosyan, Iman Kerroumi, Christina Huck, Patrick Wagner
Publikováno v:
Electroanalysis. 26:980-987
It is well known that biochemical and biotech- nological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have