V. G. Fedorkov, A. A. Smirnov, I. M. Gazizov, V. S. Khrunov, V. M. Zaletin, Yu. P. Kharitonov
Publikováno v:
Atomic Energy. 121:365-370
The results of a study of the electrophysical characteristics of the detector single crystals CdZnTe and CdTe obtained from the best domestic (Institute of Rare Metal Industry, Giredmet) and foreign (Acrorad (Japan) and Redlen (Canada)) producers are
Publikováno v:
Semiconductors. 45:636-640
The current response of a TlBr detector to 137Cs γ-ray radiation has been studied in the dose-rate range 0.033–3.84 Gy/min and within the voltage range 1–300 V; the detectors are based on pure and doped TlBr crystals grown from the melt by the B
Publikováno v:
Atomic Energy. 106:272-275
The development and investigations of uncooled semiconductor x- and γ-ray detectors based on thallium bromide crystals grown by the Bridgman-Stockbarger method are reported. The procedure for preparing Me-TlBr-Me (Me = Au, In) detector structures is
Publikováno v:
Review of Scientific Instruments. 68:553-556
Three natural diamond detectors (NDD) based spectrometry systems have been developed and used on TFTR to perform D–T neutron spectrum and flux measurements. DT neutrons interact with the NDD through the 12C(n, alpha)9Be reaction to produce a narrow
Publikováno v:
Technical Physics Letters. 26:122-124
The size and location of the area of gas breakdown at the surface of an M(GD)SM structure based on a bismuth silicate crystal was studied under uniform illumination conditions. The amount of energy absorbed in the crystal that leads to breakdown of t
Publikováno v:
Semiconductors. 33:1328-1330
Wide gap, insulating semiconductor crystals offer great promise in photoelectric devices, especially as detectors of electromagnetic and nuclear radiation, but are not widely used because they become polarized during operation. During operation of de
Publikováno v:
Soviet Atomic Energy. 63:639-641
The BDPN-1K detector assembly for neutron radiation comprises the detector and a preamplifier connected by a 10-m-long cable. The detector can be disassembled. Before the sensitive surface of the diamond there is placed a cover with a converter disk
Publikováno v:
Meditsinskaia radiologiia. 33(4)
The authors presented and analyzed the results of measurement of dose fields of photon and electron radiation using 3 types of detectors (ionization camera, Si detector and diamond detector), alternately switched on to the CADSCAN dose field analyzer
Publikováno v:
Meditsinskaia tekhnika. (3)
The article describes a device for detecting ionizing irradiation on the basis of a diamond detector and gives its characteristics. It has been shown that the diamond detector device by its parameters is superior to a similar device based on the sili