Autor:
V. N. Maller, K. D. Srivastava
Publikováno v:
IEEE Transactions on Electrical Insulation. :402-408
60 Hz and dc corona inception voltage is measured in solid-air composite insulation systems under electrical fields of varying degree of non-uniformity. Residual field due to charges deposited on the insulator surface, using dc voltages, is also meas
Autor:
M S Naidu, V N Maller
Publikováno v:
Journal of Physics D: Applied Physics. 7:1406-1411
Townsend's primary and secondary ionization coefficients α/p and γ were determined in nitrogen over a wide range of E/p (100-1000 V cm−1 Torr−1) and p (0·4 to 12 Torr at 0 °C) using the pressure variation technique. This technique, along with
Autor:
K. D. Srivastava, V. N. Maller
Publikováno v:
IEEE Transactions on Electrical Insulation. :528-535
Corona discharge currents and corona inception time delays have been measured in SF6 with an insulating support under positive switching impulses. The insulator surface charging is found to have a significant influence on the corona discharge phenome
Autor:
V. N. Maller, M. S. Naidu
Publikováno v:
IEEE Transactions on Plasma Science. 3:49-54
The sparking potentials and swarm coefficients (ionization and attachment coefficients) have been measured in sulphurhexafluoride- air and freon-nitrogen mixtures over the range of 110 ? E/p ? 240 V cm-1 torr-l and gas pressures varying between 1 and
Autor:
V. N. Maller
Publikováno v:
IEEE Transactions on Industry Applications. :724-727
Steady-state prebreakdown currents were measured under a uniform field in freon-nitrogen mixtures over the range 110? E/p?240 (E = electric field in V.cm -1 torr -1 , and p = gas pressure in torr) and at pressures ranging from 1-20 torr for different
Autor:
V. N. Maller, M. S. Naidu
Publikováno v:
IEEE Transactions on Plasma Science. 3:205-208
The ratio of diffusion coefficient to mobility (D/?) for electrons has been measured in SF6-air and freon-nitrogen mixtures for various concentrations of SF6 and freon in the mixtures over the range 140? E/p? 220 V.cm-1 - torr-1. In SF6-air mixtures,
Publikováno v:
IEEE Transactions on Electrical Insulation. :285-287
Partial discharge inception voltages (Vi) were measured in non-uniform electric fields with insulating barrier plates. The inception voltage was found to decrease with increasing thickness of barrier plate for a given electrode separation. A semi-emp
Autor:
V. N. Maller, M. S. Naidu