Zobrazeno 1 - 10
of 28
pro vyhledávání: '"V. N. Khorev"'
Publikováno v:
Measurement Techniques. 60:1199-1204
The functional capabilities of State Primary Standard GET 12–2011 of the units of magnetic induction, magnetic flux, magnetic moment, and gradient of magnetic induction are investigated for the purpose of expanding the range of measurements in the
Publikováno v:
Measurement Techniques. 55:739-744
The principles for establishing a uniform State primary standard for four basic magnetic units GET 122011, created at the Mendeleev Institute of Metrology (VNIIM) during 2007–2011, are discussed. The new standard and verification scheme have been d
Publikováno v:
Measurement Techniques. 55:177-182
An original operating standard of the unit of magnetic induction gradient, developed at the Mendeleev Institute of Metrology, is described which enables one to calibrate working standards, intended, in turn, for calibrating industrial magnetic gradio
Publikováno v:
MAPAN. 24:9-14
The magnetic field of a single-layer solenoid (length L=1020 mm, average radius R=114.67 mm, pitch p=1.0001 mm and wire diameter d=0.799 mm) with a multi-current method was calculated to improve the uniformity and optimized by using Legendre polynomi
Publikováno v:
Physics of the Earth and Planetary Interiors. 166:147-152
The results of calibration of proton, cesium, potassium and helium–cesium scalar magnetometers in the range 20–100 μT are discussed. The calibration made it possible to estimate errors and to apply corrections to reduce the uncertainty of measur
Publikováno v:
Review of Scientific Instruments. 73:3107-3111
A standard system for low magnetic fields has been developed at the Korea Research Institute of Standards and Science. The system consists of a precision solenoid, He–Cs atomic magnetic resonance magnetometer, and apparatus for three-axis compensat
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 48:196-199
Tesla-to-ampere ratio giving the largest error in the /spl gamma/'/sub P/-low-field-experiment has been determined using a modified noncontacting method. The total uncertainty of 0.164/spl times/10/sup -6/ has been attained. The constant of a solenoi
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 47:638-643
The proton gyromagnetic ratio in water has been measured by the low field method using atomic magnetic resonance in /sup 4/He, a multicurrent solenoid and an induction method for the dimensional measurement of the solenoid. The result for air and vac
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 54:727-729
A wide-range low permanent field standard measurement system is described, intended for use within the geomagnetic range of natural magnetic fields on the Earth's surface (EMF) (20 μT - 100 μT), fields of near and distant outer space (0.1 μT - 20
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 52:433-435
At the D. I. Mendeleyev Institute for Metrology (VNIIM), a standard system using /sup 4/He atomic magnetic resonance, has been operating for the past 10 years in a long-term investigation into the reproducibility of low magnetic flux densities and di