Purpose. The complex approach to calculating thunderstorm overvoltage on substation equipment is considered when lightning strikes in a lightning rod. Methodology. The conditions of safe passage of lightning current through a lightning arrester are f
Externí odkaz:
https://doaj.org/article/2fc654551b054f66a74dab98e830499a
Autor:
I. V. Nizhevskyi, V. I. Nizhevskyi
Publikováno v:
Electrical engineering & Electromechanics, Iss 3, Pp 68-71 (2018)
Purpose. The measurements of the resistance of grounding devices for various purposes using a three-electrode installation under real conditions are considered. Methodology. On the basis of the use of a three-electrode installation, a technique for f
Externí odkaz:
https://doaj.org/article/196f2026b4a74c61a3c9db7f367246cf
Publikováno v:
Electrical engineering & Electromechanics, Iss 6, Pp 60-64 (2016)
Purpose. The paper considers experimental research of three-electrode units for measuring the resistance of grounding devices for different purposes. Methodology. The experimental study of the method of resistance measurement of grounding devices for
Externí odkaz:
https://doaj.org/article/384e729789a940b789339bc7004da1c8
Publikováno v:
Electrical engineering & Electromechanics, Iss 2, Pp 72-75 (2015)
Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her electrical equipment. These req
Externí odkaz:
https://doaj.org/article/a5535cea18a44fca965e6be43ac7161a
Autor:
V. I. Nizhevskyi, I. V. Nizhevskyi
Publikováno v:
Electrical Engineering & Electromechanics; № 3 (2019): Electrical Engineering & Electromechanics №3 2019; 67-73
Электротехника и Электромеханика; № 3 (2019); 67-73
Електротехніка і Електромеханіка; № 3 (2019): Електротехніка і Електромеханіка №3 2019; 67-73
Electrical engineering & Electromechanics, Iss 3, Pp 67-73 (2019)
Электротехника и Электромеханика; № 3 (2019); 67-73
Електротехніка і Електромеханіка; № 3 (2019): Електротехніка і Електромеханіка №3 2019; 67-73
Electrical engineering & Electromechanics, Iss 3, Pp 67-73 (2019)
Разработан инженерный подход к расчету грозовых перенапряжений на оборудовании подстанции при ударе молнии в молниеотвод. Сформулиров
Publikováno v:
Electrical engineering & Electromechanics, Iss 4, Pp 71-77 (2014)
Results of research on distribution of electric potentials on the earth surface in the territory with a grounding conductor are analyzed. It is shown that potential over the center of a square grounding conductor can be higher than that over the elec
Autor:
I. V. Nizhevskyi, V. I. Nizhevskyi
Publikováno v:
Electrical Engineering & Electromechanics; № 3 (2016): Electrical Engineering & Electromechanics №3 2016; 50-57
Электротехника и Электромеханика; № 3 (2016): Электротехника и Электромеханика №3 2016; 50-57
Електротехніка і Електромеханіка; № 3 (2016): Електротехніка і Електромеханіка №3 2016; 50-57
Electrical engineering & Electromechanics, Iss 3, Pp 50-57 (2016)
Электротехника и Электромеханика; № 3 (2016): Электротехника и Электромеханика №3 2016; 50-57
Електротехніка і Електромеханіка; № 3 (2016): Електротехніка і Електромеханіка №3 2016; 50-57
Electrical engineering & Electromechanics, Iss 3, Pp 50-57 (2016)
Introduction. Measurement of resistance of the grounding device (GD) by means of a three-electrode system. This requires not only the right choice of installation locations of measuring electrodes, but also the determination of the point of zero pote