Zobrazeno 1 - 10
of 17
pro vyhledávání: '"V. Brailovskii"'
Autor:
M. R. Filonov, V. Brailovskii, S. M. Dubinskii, S. D. Prokoshkin, A. S. Konopatskii, Karine Inaekyan, Yu. S. Zhukova
Publikováno v:
Metal Science and Heat Treatment. 61:333-339
Ti – Zr-based alloys with a high zirconium content prepared by vacuum-arc remelting with nonconsumable tungsten electrode are studied. The optimum number of remelting operations and melting conditions in order to achieve a highly uniform distributi
Autor:
V. Brailovskii, Xuan Ta Dinh, Sergey Prokoshkin, S. P. Galkin, V. A. Sheremet’ev, A. A. Kudryashova
Publikováno v:
Metallurgist. 63:51-61
Prospects are presented for the technology of preparing biomedical Ti–Zr–Nb shape memory alloy 3–8 mm diameter bars more than 2000 mm long using an advanced combination of radial shear rolling and rotary forging. Radial shear rolling parameters
Publikováno v:
Physics of Metals and Metallography. 119:134-145
Differential scanning calorimetry has been used to study the effect of the temperature and holding time upon isothermal annealing on the calorimetric effects of the martensitic transformations (MTs) of an aging Ti–50.7 at % Ni alloy produced by hot
Publikováno v:
Tekhnologiya i Konstruirovanie v Elektronnoi Apparature, Iss 1, Pp 13-16 (2015)
The paper presents the methodology and experimental results of the study of human eye sensitivity in central and peripheral vision field to the visible light pulses. The experimental results show that transmission systems based on visible rays can wo
Autor:
V. V. Brailovskii
Publikováno v:
Instruments and Experimental Techniques. 53:284-287
A pulse nuclear quadrupole resonance (NQR) spectrometer intended for studying the resonance signal spectra of nuclei of solid substances in a 1- to 30-MHz band is described. The pulse duration of excitation pulses is regulated from 10 to 100 μs at a
Publikováno v:
Instruments and Experimental Techniques. 52:230-233
An increase in the sensitivity of a pulse-type detector for the nuclear quadrupole resonance spectrometer has been attained by optimizing the delay time for switching on the receiver after termination of an excitation pulse and by using an original c
Publikováno v:
Instruments and Experimental Techniques. 45:732-733
A continuous-flow thermostat design for a nuclear quadrupole resonance thermometer probe is described. This design makes it possible to significantly decrease the length of the coaxial line connecting the inductance coil to the autodyne and to increa
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
Measurement Techniques. 31:338-341