Zobrazeno 1 - 10
of 21
pro vyhledávání: '"V M Maksimenko"'
Publikováno v:
Journal of Applied Spectroscopy. 75:15-20
EPR spectra of barium dithionate hydrate single crystals γ-irradiated at low (80 Gy) and high (10 kGy) doses are studied. Four lines, the strongest of which is due to the SO3− radical, are observed in the EPR spectrum of the low-irradiated samples
Autor:
V. G. Denisova, R. A. Mukhamedshin, V. S. Puchkov, Z. M. Guseva, V. M. Maksimenko, E. A. Kanevskaya, A. E. Morozov
Publikováno v:
Bulletin of the Russian Academy of Sciences: Physics. 73:618-620
Spectra of secondary particles (γ-rays) in γ-families detected in the X-ray chambers in the Pamirs (H = 600 g cm−2) have been analyzed. These γ-ray spectra show a bend at the energy E*γ ≈ (ΣEγ)min, where (ΣEγ)min is the lowest total energ
Autor:
Z. M. Guseva, V. S. Puchkov, S. A. Slavatinskii, V. G. Denisova, A. V. Vargasov, V. M. Maksimenko, A. S. Borisov, E. A. Kanevskaya, S. E. Pyatovskii
Publikováno v:
Bulletin of the Russian Academy of Sciences: Physics. 71:516-518
γ Families with halos detected in the “Pamir” experiment have been analyzed. Comparison of the experimental data with the results of calculation within the quark-gluon string model (MC0 code) made it possible to determine the efficiency of halo
Autor:
O. A. Bugay, T. L. Petrenko, V. V. Teslenko, S. P. Kolesnik, Marc F. Desrosiers, V. M. Maksimenko, M. P. Baran
Publikováno v:
Radiation Protection Dosimetry. 120:202-204
Electron paramagnetic resonance (EPR) dosimetry is growing in popularity and this success has encouraged the search for other dosimetric materials. Previous studies of gamma-irradiated barium dithionate (BaS(2)O(6) x 2H(2)O) have shown promise for it
Publikováno v:
Health physics. 98(2)
The response of alanine and barium dithionate EPR dosimeters to proton irradiation with energies ranging from 6.6―25 MeV has been investigated. EPR dosimeters were calibrated using calibrated gamma sources. Alanine dosimeters show a value 29 % high
Publikováno v:
Solid State Communications. 81:55-58
Comparative behaviour of the conduction electrons state density on the Fermi surface was studied by the conduction electrons spin resonance (ESR) method in the Cr20Ni16Mn6 steel type with carbon and nitrogen. It was shown that the state density incre
Publikováno v:
Physica Status Solidi (a). 127:405-414
Peculiarities of properties and formation of the thermal donors (TD) in Cz-Si crystals with different carbon content are investigated by ESR and Hall effect methods after long-time (up to 500 h) annealing within the temperature range from 450 to 550
Autor:
S P, Gashchak, Iu A, Makliuk, A M, Maksimenko, V M, Maksimenko, V I, Martynenko, I V, Chizhevskiĭ, M D, Bondar'kov, T A, Mousseau
Publikováno v:
Radiatsionnaia biologiia, radioecologiia. 48(1)
Radioactive contamination of small birds (484 individuals, 44 species) was investigated in the Chernobyl zone (Ukraine) in 2003-2005. Values variation of 90Sr and of 137Cs activity concentration reached 3-4 orders of magnitude even in one site, and m
Autor:
Ian Bailiff, L.G. Khamidova, J. Puskar, Victor Minenko, N. P. Baran, L. Pasalskaya, Robert B. Hayes, I.M. Fedosov, V. Radchuk, Gerry H. Kenner, V. Skvortzov, Edwin H. Haskell, J. Past, V. Finin, Sergey Sholom, Alexander Ivannikov, V. M. Maksimenko, U. Vaher, S. Dubovsky, V. Kirillov, I. A. Likhtarev, V.F. Stepanenko, Vadim V. Chumak, Albrecht Wieser, S. Kolesnik, Georg Liidja, A. A. Bugai, A. Meijer, Endel Lippmaa
Publikováno v:
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 47(11-12)
Intercomparison of EPR-dosimetric techniques using tooth enamel had been performed in order to check whether the results produced by different laboratories are consistent and accurate. Participants were supposed to evaluate doses applied to pulverize
Autor:
V. M. Maksimenko, Ye. E. Smuk, V.G. Gavriljuk, N. P. Baran, B. D. Shanina, S. P. Efimenko, S. Yu. Smuk
Publikováno v:
Physical review. B, Condensed matter. 48(5)
Electron-spin resonance was studied in the Cr 21 Ni 16 Mn 7 and Cr 20 Ni 16 Mn austenites with different content of nitrogen and carbon. Measurements were made in the temperature region 10-300 K. Temperature dependences were obtained for the absorpti