Zobrazeno 1 - 10
of 20
pro vyhledávání: '"Uma, Uzubi"'
Autor:
Uma Uzubi Uma, Daniel Nmadu, Nnaemeka Ugwuanyi, Ogah Ekechi Ogah, Ngozi Eli-Chukwu, Marcellinus Eheduru, Arthur Ekwue
Publikováno v:
Protection and Control of Modern Power Systems, Vol 8, Iss 1, Pp 1-19 (2023)
Abstract The operational performance of conventional overcurrent protection relay coordination connected to a distribution network is adversely affected by the penetration of distributed generators (DG) at different buses in the network. To address t
Externí odkaz:
https://doaj.org/article/81dda6b05e70484fbddda5313574d659
Autor:
Eli-Chukwu, Ngozi Clara, Igbokwe, Innocent Chiawa, Ifebude, Barnabas, Nmadu, Daniel, Iguodala, Wilfred, Uma, Uzubi, Onyeneke, Robert Ugochukwu, Akudo, Florence Ukamaka
Publikováno v:
Journal of Applied Research in Higher Education, 2022, Vol. 15, Issue 1, pp. 238-253.
Externí odkaz:
http://www.emeraldinsight.com/doi/10.1108/JARHE-09-2021-0346
Publikováno v:
Scientific African, Vol 9, Iss , Pp e00528- (2020)
The conventional distance protection scheme is usually affected by uncertainties associated with transmission line parameters and some uncontrolled parameters like fault resistances. By varying the fault resistances, errors are introduced in the faul
Externí odkaz:
https://doaj.org/article/ec956718c5c84aba9e95a1eca8dcc24d
Publikováno v:
Journal of Electrical Engineering & Technology. 16:1867-1877
FACTS devices are presently used to improve the power transfer capability of a transmission line and voltage stability of a power system network. Shunt injected current (Ish) by the Static Var Compensators (SVC) causes underreach or overreach of dist
Publikováno v:
Journal of Electrical Engineering & Technology. 16:131-140
The availability of zero-sequence current, under normal circumstances, determines the accuracy of the operation of a distance relay which is connected to a mutually coupled parallel line. When this is not available, the system adopts a different comp
Publikováno v:
2021 IEEE PES/IAS PowerAfrica.
The proper understanding of the nature and sources of low-frequency oscillations presents a problem for power systems in developing countries because of the inherent continuous network expansion and overloading. In this paper, a thorough study of osc
The power systems in developing countries are usually stressed and operated near their stability limits. Consequently, accurate sources of oscillations and their controls can present a challenge. This paper reports a comprehensive study of the oscill
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::41101c74f13fb4dbce9f897526fcb721
https://doi.org/10.36227/techrxiv.15066915
https://doi.org/10.36227/techrxiv.15066915
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
2020 IEEE PES/IAS PowerAfrica.
The variation of fault resistances introduces error in the measured apparent impedance of the conventional distance protection scheme. With this, the measured apparent impedance at the relay location is not proportional to its length. This paper pres
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.