Zobrazeno 1 - 10
of 19
pro vyhledávání: '"Uliana Danilenko"'
Autor:
Ashley Ribera, Li Zhang, Carla Ribeiro, Norma Vazquez, Janet Thonkulpitak, Julianne C. Botelho, Uliana Danilenko, Katleen van Uytfanghe, Hubert W. Vesper
Publikováno v:
Journal of Mass Spectrometry and Advances in the Clinical Lab, Vol 29, Iss , Pp 9-15 (2023)
Background: Free thyroxine (FT4) measurement is one of the most requested tests in patient care for diagnosing and treating thyroid-related illnesses. Equilibrium dialysis (ED) is considered the “gold standard” for FT4 measurement; however, sever
Externí odkaz:
https://doaj.org/article/3abe1be8e22240a2a69f50fbaa89c2c3
Publikováno v:
The Journal of Applied Laboratory Medicine. 7:1251-1254
Autor:
Alicia N. Lyle, Jeffrey R. Budd, Victoria M. Kennerley, Bianca N. Smith, Uliana Danilenko, Christine M. Pfeiffer, Hubert W. Vesper
Publikováno v:
Clinical Chemistry and Laboratory Medicine (CCLM).
Objectives The clinical use of soluble transferrin receptor (sTfR) as an iron status indicator is hindered by a lack of assay standardization and common reference ranges and decision thresholds. In 2009, the WHO and National Institute for Biological
Autor:
Ashley Ribera, Li Zhang, Amonae Dabbs-Brown, Otoe Sugahara, Krista Poynter, Katleen van Uytfanghe, Eri Shimizu, Antonius E. van Herwaarden, Julianne C. Botelho, Uliana Danilenko, Hubert W. Vesper
Publikováno v:
Clinical Biochemistry, 116, 42-51
Clinical Biochemistry, 116, pp. 42-51
Clinical Biochemistry, 116, pp. 42-51
Item does not contain fulltext BACKGROUND: Accurate and reliable measurement of human serum free thyroxine (FT4) is critical for the diagnosis and treatment of thyroid diseases. However, concerns have been raised regarding the performance of FT4 meas
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::76d03e353517532a2b10f5c32130baac
https://doi.org/10.1016/j.clinbiochem.2023.03.010
https://doi.org/10.1016/j.clinbiochem.2023.03.010
Autor:
Jamie Tam, Uliana Danilenko, Carol H. Christensen, Joanne T. Chang, Hoda T. Hammad, Babita Das, Dana M. van Bemmel, Cindy M. Chang, Juan C. Vivar
Publikováno v:
Cancer Epidemiol Biomarkers Prev
Background: While smokeless tobacco (ST) causes oral cancer and is associated with cardiovascular diseases, less is known about how its effects differ from other tobacco use. Biomarkers of potential harm (BOPH) can measure short-term health effects s
Autor:
Otoe Sugahara, Ashley Ribera, Uliana Danilenko, Lynn Collins, Tatiana Buchannan, Clark Coffman, Norma Vazquez, Fidelia Pokuah, Li Zhang, Alicia N Lyle, Vesper Hubert, Janet Thonkulpitak
Publikováno v:
Journal of the Endocrine Society. 6:A759-A760
Concerns about the accuracy and reliability of thyroid function tests, especially free thyroxine (FT4), have been stated by the clinical laboratory community for many years. Thyroid function tests are the most used tests in the U. S. and are the only
Publikováno v:
Journal of the Endocrine Society. 6:A664-A665
Assessment of free testosterone (FT) has been recommended in recent clinical practice guidelines as a biomarker for diagnosis and management of testosterone related disorders such as male testosterone deficiency due to hypogonadism and female androge
ODP479 Equilibrium Dialysis ID-LC/MS/MS Procedure for Routine Measurement of Free Thyroxine in Serum
Autor:
Li Zhang, Ashley Ribera, Zachary D’Zio, Otoe Sugahara, Cindy Tse, Uliana Danilenko, Vesper Hubert
Publikováno v:
Journal of the Endocrine Society. 6:A765-A765
Free thyroxine (FT4) test is essential for diagnosis of thyroid diseases. Most FT4 tests used in patient care are immunoassays (IAs). However, concerns about the accuracy of FT4 IAs have been raised in the clinical laboratory community. Reference mea
Autor:
Chui Tse, Li Zhang, Komal Dahya, Fidelia Pokuah, Otoe Sugahara, Uliana Danilenko, Hubert Vesper
Publikováno v:
Journal of the Endocrine Society. 6:A305-A305
According to the CDC's National Diabetes Statistics Report for 2020, it is estimated that 34.2 million, 10.5% of the U. S. population, have diabetes. High fructose intake has also been associated with increased de novo lipogenesis in the liver leadin
Autor:
W. Greg Miller, Uliana Danilenko, Gary L. Myers, Patric A Clapshaw, Johanna E. Camara, Hubert W. Vesper
Publikováno v:
Clin Chem Lab Med
Manufacturers of in vitro diagnostic medical devices, clinical laboratories, research laboratories and calibration laboratories require commutable reference materials that can be used in the calibration hierarchies of medical laboratory measurement p