Zobrazeno 1 - 10
of 60
pro vyhledávání: '"U. Akar Tarim"'
Publikováno v:
Radiation Physics and Chemistry. 188:109581
Measurements show the detection efficiency of the NaI(Tl) detector depends on the source-detector configuration. In this work, the geometrical and intrinsic detection efficiencies of the 2in both in height and diameter and 3in both in height and diam
Publikováno v:
Radiation Physics and Chemistry. 106:170-174
The response functions of backscattered photons, which are initially collimated with an energy of 662 keV, were obtained by a Monte Carlo method in an NaI(Tl) scintillation detector using a suitcase or briefcase full of paper, clothing, ammonium nitr
Autor:
U. Akar Tarim
Publikováno v:
Acta Physica Polonica A. 130:233-235
A Monte Carlo code was written to determine the saturation thickness for multiply scattered gamma rays from aluminium targets. Interactions of incident gamma rays with the energies of 123, 279, 360, 511, 662, 1115, and 1250 keV were simulated. This w
Autor:
O. Gurler, U. Akar Tarim
Publikováno v:
Acta Physica Polonica A. 130:236-238
Bu çalışma, 14-19 Ekim 2015 tarihleri arasında Antalya[Türkiye]’da düzenlenen 2. International Conference on Computational and Experimental Science and Engineering (ICCESEN)’da bildiri olarak sunulmuştur. A Monte Carlo code is proposed for
Publikováno v:
Radiation Effects and Defects in Solids. 169:232-238
The energy deposited by gamma radiation from the Cs-137 isotope into body tissues (bone and muscle), tissue-like medium (water), and radiation shielding materials (concrete, lead, and water), which is of interest for radiation dosimetry, was obtained
Publikováno v:
Annals of Nuclear Energy. 58:198-201
We developed a simple Monte Carlo code to determine the mass attenuation coefficients of some soil samples at nine different gamma-ray energies (59.5, 80.9, 122.1, 159.0, 356.5, 511.0, 661.6, 1173.2 and 1332.5 keV). Results of the Monte Carlo calcula
Publikováno v:
Radiation Physics and Chemistry. 85:12-17
A Monte Carlo simulation study has been conducted of 60Co photons Compton scattered in concrete, illustrating the degraded energy spectra of gamma-ray radiation. Results are produced representing a NaI(Tl) detector model. We were able to analyse ener
Publikováno v:
Journal of Radioanalytical and Nuclear Chemistry. 295:901-905
We have written a Monte Carlo code to simulate the experimental results of a previously reported study. We were able to analyse the energy distributions of photons that reached the detector system after suffering several successive Compton scattering
Publikováno v:
Radiation Physics and Chemistry. 81:745-748
Investigation is made on the energy spectrum of photons originating from interactions of 662 key primary gamma-ray photons emitted by a point source positioned at the centre of a water equivalent solid phantom of dimensions 19 cm x 19 cm x 24 cm. Pea
Autor:
U. Akar Tarim, O. Gurler
Publikováno v:
Journal of Radioanalytical and Nuclear Chemistry. 293:397-401
The radiation attenuation coefficients mu/rho (cm(2) g(-1)) for concrete and cement samples that used for experimental studies by other researchers were determined by Monte Carlo calculations at 59.5, 80, 356, 661.6, 1173.2 and 1332.5 keV photon ener