Zobrazeno 1 - 10
of 63
pro vyhledávání: '"Tsirul'nikov Em"'
Publikováno v:
Neurophysiology. 24:339-343
Focused ultrasound has been used to elicit cutaneous tactile, thermal, specific and nonspecific pain sensations, and also subcutaneous (deep) sensations which included tactile and some pain sensations (muscular and periosteal etc.). It has been found
Publikováno v:
Pain. 67(1)
Short pulses of focused ultrasound can stimulate the superficial and deep-seated receptor structures of human tissues and induce different somatosensory sensations including, in particular, pain sensations. Focused ultrasound as a new artificial stim
Publikováno v:
Ultrasound in medicinebiology. 22(2)
The feasibility of the use of focused ultrasound for stimulation of the superficial and deep-seated receptor structures of humans and animals are presented in this review article. Applications of this method in physiology, for research into somatosen
Publikováno v:
The Journal of the Acoustical Society of America. 123:3790-3790
We have previously shown that short pulses of focused ultrasound may be used to stimulate locally receptor neural structures and thereby induce sensations that humans can perceive through the skin (for example tactile, warmth and cold, tickling, pain
Akademický článek
Tento výsledek nelze pro nepřihlášené uživatele zobrazit.
K zobrazení výsledku je třeba se přihlásit.
K zobrazení výsledku je třeba se přihlásit.
Publikováno v:
The Journal of the Acoustical Society of America. 90:1209-1209
Publikováno v:
Brain Research. 135:279-285
The possibility of stimulation of receptor structures with focused ultrasound (focused beam of high frequency mechanical waves) was investigated. Stimulation of single Pacinian corpuscle isolated from cat's mesentery resulted in receptor and action p
Autor:
Grigoryi V. Gersuni, I. A. Vartanyan, Pudov Vi, Leonid R. Gavrilov, Tsirul'nikov Em, A.S. Rosenblyum
Publikováno v:
Ultrasound in Medicine & Biology. 14:277-285
Focused ultrasound with a frequency of 2.5 MHz and amplitude-modulated in the range of audiometric frequencies (125–8000 Hz) was employed to examine 50 normal hearing persons and in complex diagnostics of over 500 patients suffering from sensorineu
Publikováno v:
Zhurnal evoliutsionnoi biokhimii i fiziologii [Zh Evol Biokhim Fiziol] 2004 Sep-Oct; Vol. 40 (5), pp. 476-80.
Autor:
Lebedev VP, Il'inskiĭ OB, Savchenko AB, Kolosova LI, Kovalevskiĭ AV, Tsirul'nikov EM, Rychkova SV, Malikhova MV, Aleksandrov VA, Gerasimova LI, Pavlov VA
Publikováno v:
Meditsinskaia tekhnika [Med Tekh] 2002 Nov-Dec (6), pp. 32-5.