Zobrazeno 1 - 10
of 943
pro vyhledávání: '"Transformer types"'
Publikováno v:
IEEE Transactions on Power Delivery. 35:1048-1057
Accurate zero-sequence transformer data is important for correct fault analysis and protection settings. Utilities have been forced to approximate zero-sequence impedances for many three-legged core power transformers in service today that did not un
Autor:
Paweł Albrechtowicz
Publikováno v:
Energies; Volume 14; Issue 16; Pages: 5049
Energies, Vol 14, Iss 5049, p 5049 (2021)
Energies, Vol 14, Iss 5049, p 5049 (2021)
Phase-shifting transformers are effective elements used to control power flows in many power systems. Their positive influence on power flows has been proved in the literature. However, the efficiency of phase-shifting transformers has not been analy
Publikováno v:
2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON).
The emergence of large concentrated loads in urban facilities requires new technical solutions for their power supply. 10–20 kV transformer substation of large power with dry type insulation instead oil type insulation more often use in modern Latv
Publikováno v:
IEEE Transactions on Circuits and Systems II: Express Briefs. 65:1594-1598
A network-synthesis procedure for a new low-pass real-to-real (resistance-to-resistance) impedance transformer is presented. Conventionally, the well-known impedance transformer had an all-pole transmission function, and suffered from a theoretical l
Autor:
Deepak Divan, Hao Chen
Publikováno v:
IEEE Transactions on Power Electronics. 33:2933-2947
This paper presents a new topology for a fully bidirectional soft-switching solid-state transformer (S4T). The minimal topology, featuring 12 main devices and a high-frequency transformer, does not use an intermediate dc voltage link, and provides si
Publikováno v:
IEEE Transactions on Industrial Electronics. 65:2904-2914
This paper proposes a three-phase lines to single-phase coil planar contactless power transformer. The transformer has the primary consisting of three-phase line cables arrayed in parallel on a plane and the secondary of single-phase coil. The propos
Publikováno v:
IEEE Transactions on Industrial Electronics. 65:2245-2255
In this paper, we propose an approach for integrating a series filter inductance in a coaxially wound transformer (CWT) as a potential alternative to conventional solenoidally wound transformers (SWT) for high-power isolated soft-switching dc–dc co
Publikováno v:
IEEE Access. 6:28193-28202
Bandpass impedance transformers (BPIMTs) with extremely high transforming ratios by adopting the proposed $\Pi $ -tapped feeds are realized in this paper. $\Pi $ -tapped feeds composed of two shunt stubs and one-section line performing the impedance
Autor:
Ali H. Ali, Athar Hussein Mohammed
Publikováno v:
Journal of Physics: Conference Series. 1963:012173
There are many algorithms used in Natural Language Processing( NLP) to achieve good results, such as Machine Learning (ML), Deep Learning(DL) and many other algorithms. In Natural Language Processing,the first challenges is to convert text to numbers
Publikováno v:
IAS Annual Meeting
This paper presents the design and implementation of the 60-Hz ferroresonant transformer (FRT) for the light emitting diode (LED) street lamp to achieve high-frequency (HF) noise attenuation and ac-line voltage clamping. The HF transformer (HFT) used