Publikováno v:
Aquaculture. 452:9-11
Blood fluke infection is one of the main causes of mortality in cultured juvenile Pacific bluefin tuna Thunnus orientalis (PBT) in Japan. We investigated 532 wild juvenile PBT of four different fish groups caught for tuna culture seed stock from off
Publikováno v:
Fisheries Research. 102:217-220
We investigated the geographical origin and migration of anchovy Engraulis japonicus in Tachibana Bay, western Japan, using carbon and nitrogen stable isotope ratios (δ13C and δ15N, respectively). Stable isotope ratios of anchovy varied among seaso
Autor:
Eiichi, Sato, Seiichiro, Nomiya, Keitaro, Hitomi, Hideaki, Onabe, Toshiaki, Kawai, Akira, Ogawa, Shigehiro, Sato, Toshio, Ichimaru
Publikováno v:
岩手医科大学共通教育研究年報. 42:7-11
A simple x-ray computed tomography(CT) system utilizing a cadmium telluride detector is described. The CT system is of the first generation type and consists of an x-ray generator, a turn table, a translation table, a motor drive unit, a cadmium tell
Autor:
Eiichi, Sato, Seiichiro, Nomiya, Keitaro, Hitomi, Hideaki, Onabe, Toshiaki, Kawai, Akira, Ogawa, Shigehiro, Sato, Toshio, Ichimaru
Publikováno v:
岩手医科大学共通教育研究年報. 42:1-5
The construction of a photon-counting x-ray computed tomography(CT) system utilizing a cadmium telluride(CdTe) detector is described. The CT system is of the first generation type and consists of an x-ray generator, a turn table, a translation table,
Publikováno v:
Fisheries Science. 72:855-859
The purpose of this study was to determine the growth and reproductive characteristics of round scad Decapterus maruadsi in the East China Sea. The characteristics regarding growth and reproduction of round scad based on otolith reading and gonad his
Publikováno v:
NIPPON SUISAN GAKKAISHI. 72:21-26
1998~2004 年の 4~8 月に長崎県五島列島沖および鹿児島県屋久島沖で採集したホソアオトビ Hirundichthys oxycephalus の卵を顕微鏡下で観察した。本種の卵は片側に直径 20 μm の纏絡糸が 1 本と
Autor:
Eiichi, Sato, Akira, Yamadera, Michiaki, Sagae, Toshio, Ichimaru, Norihiko, Morino, Motoki, Ikeda, Chie, Sasaki, Etsuro, Tanaka, Hidezo, Mori, Toshiaki, Kawai, Fumihito, Ito, Shigehiro, Sato, Kazuyoshi, Takayama, Hideaki, Ido
Publikováno v:
岩手医科大学教養部研究年報. 39:1-9
The cerium-target x-ray tube is useful in order to perform cone-beam K-edge angiography because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast media. The x-ray generator consists of a main cont
Autor:
Eiichi, Sato, Etsuro, Tanaka, Hidezo, Mori, Toshiaki, Kawai, Toshio, Ichimaru, Shigehiro, Sato, Kazuyoshi, Takayama, Hideaki, Ido
Publikováno v:
岩手医科大学教養部研究年報. 39:11-17
Energy-selective enhanced K-edge angiography utilizing a conventional x-ray generator is described. The x-ray generator is SOFRON NST-1005, and the maximum tube voltage and current are 100 kV and 5 mA, respectively. In the present research, the tube
Autor:
Shigehiro Sato, Eiichi Sato, Hideaki Ido, Toshio Ichimaru, Etsuro Tanaka, Hidezo Mori, Kazuyoshi Takayama, Toshiaki Kawai
Publikováno v:
Medical Physics. 32:49-54
The high-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV by a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing gap switches in the surge ge
Autor:
Hidezo Mori, Toshiaki Kawai, Eiichi Sato, Toshio Ichimaru, Hideaki Ido, Kazuyoshi Takayama, Etsuro Tanaka, Shigehiro Sato
Publikováno v:
Medical Physics. 31:3017-3021
The cerium target x-ray generator is useful in order to perform enhanced K-edge angiography using a cone beam because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. The x-ray generator