Zobrazeno 1 - 10
of 12
pro vyhledávání: '"Tim Soetens"'
Publikováno v:
Materials Proceedings, Vol 6, Iss 1, p 17 (2021)
The chloride-induced corrosion of steel reinforcement is one of the main causes of deterioration of reinforced concrete structures. Cathodic protection (CP) of steel in concrete is a widely accepted repair technique to reduce, or completely stop, rei
Externí odkaz:
https://doaj.org/article/4abfbe9bc61346a19a0c8ab7774d6df1
Publikováno v:
RILEM Bookseries ISBN: 9783031217340
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::3bcd0901bfe7e0cf4de31fa627e41c80
https://doi.org/10.1007/978-3-031-21735-7_90
https://doi.org/10.1007/978-3-031-21735-7_90
Autor:
Györgi Balazs, Joaquim Boshoff, Marco di Prisco, Terje Kanstad, Wolfgang Kusterle, Bruno Massicotte, Giovanni Plizzari, Pierre Rossi, Pedro Serna Ros, Tim Soetens, Bo Tvede-Jensen, Ab Van den Bos
Publikováno v:
fib Bulletin 105. Fibre Reinforced Concrete ISBN: 9782883941625
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d91464c868631d6d7ac6c07ce2df7ffb
https://doi.org/10.35789/fib.bull.0105.ch06
https://doi.org/10.35789/fib.bull.0105.ch06
Publikováno v:
MATEC Web of Conferences. 361:01002
Due to the booming construction wave between the 60´s and 80´s, a lot of reinforced concrete structures are now approaching their intended service life design. Concerning the industrial sector, an unforeseen shutdown of production processes due to
Publikováno v:
MATEC Web of Conferences. 364:04020
Galvanic cathodic protection (GCP) of steel in concrete by means embedded discrete anodes is a commonly used repair method to reduce or prevent steel reinforcement corrosion. The design and efficiency of the system depends greatly on the corrosion ac
Publikováno v:
MATEC Web of Conferences. 361:01009
Electrochemical repair by means of impressed current cathodic protection (ICCP) was adopted as a repair strategy for a reinforced concrete slab, severely damaged by chloride induced reinforcement corrosion. Since the slab is located within an ATEX-zo
Publikováno v:
Construction and Building Materials. 310:125187
The design of a galvanic cathodic protection (GCP) system with embedded discrete anodes for chloride contaminated reinforced concrete is greatly affected by the throwing power of the system. In this research, the influence of environmental conditions
Autor:
Tim Soetens, Stijn Matthys
Publikováno v:
Cement and Concrete Composites. 82:1-13
The ability of cracked reinforced concrete to transfer shear stresses is of major importance for concrete members designed to sustain high shear forces. Thereby, the maximum shear capacity is mainly affected by the aggregate interlock mechanism, the
Different methods to model the post-cracking behaviour of hooked-end steel fibre reinforced concrete
Autor:
Tim Soetens, Stijn Matthys
Publikováno v:
Construction and Building Materials. 73:458-471
When designing an element made of steel fibre reinforced concrete (SFRC) subjected to bending, the post-cracking residual stress capacity is taken into consideration. Characterization of this residual flexural capacity is generally performed by means
Autor:
Stijn Matthys, Tim Soetens
Publikováno v:
High Tech Concrete: Where Technology and Engineering Meet ISBN: 9783319594705
Recent developments and ongoing research in the field of steel fibre reinforced concrete (SFRC) have led to its implementation into national and international design codes and guidelines. Since fibres are promising as an alternative for (minimum) she
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::3fa4a88ba58abf9d19fdbeca59af5b26
https://doi.org/10.1007/978-3-319-59471-2_45
https://doi.org/10.1007/978-3-319-59471-2_45