Zobrazeno 1 - 10
of 16
pro vyhledávání: '"Tianjun Lin"'
Publikováno v:
Yuanzineng kexue jishu, Vol 57, Iss 4, Pp 704-712 (2023)
The random forest algorithm was applied to study the nuclear binding energy and charge radius. The regularized root-mean-square of error (RMSE) was proposed to avoid overfitting during the training of random forest. RMSE for nuclides with Z, N>7 is r
Externí odkaz:
https://doaj.org/article/0315c9c93edc48b0b62f7aa12ef76285
Publikováno v:
Sensors and Actuators A: Physical
Sensors and Actuators A: Physical, 2017, 267, pp.318-326. ⟨10.1016/j.sna.2017.10.029⟩
Sensors and Actuators A: Physical, 2017, 267, pp.318-326. ⟨10.1016/j.sna.2017.10.029⟩
International audience; In this paper we present the investigation results on the dielectric properties of glucose aqueous solutions over a large frequency band spanning from 2 to 18 GHz. The characterization at room temperature (25 °C) of solutions
Publikováno v:
48th European Microwave Conference, EuMC 2018
48th European Microwave Conference, EuMC 2018, Sep 2018, Madrid, Spain. pp.1053-1056, ⟨10.23919/EuMC.2018.8541554⟩
48th European Microwave Conference, EuMC 2018, Sep 2018, Madrid, Spain. pp.1053-1056, ⟨10.23919/EuMC.2018.8541554⟩
International audience; In this paper we report a resolution enhancement method for non-destructive imaging application with near-field scanning microwave microscopy (NFMM). The technique proposed for the image processing is based on the combination
Publikováno v:
47th European Microwave Conference, EuMC 2017
47th European Microwave Conference, EuMC 2017, Oct 2017, Nuremberg, Germany. pp.827-830, ⟨10.23919/EuMC.2017.8230972⟩
47th European Microwave Conference, EuMC 2017, Oct 2017, Nuremberg, Germany. pp.827-830, ⟨10.23919/EuMC.2017.8230972⟩
International audience; In this paper an experimental investigation of the lateral resolution of a homemade near field microwave microscope (NFMM) is reported. The optimal lateral resolution is studied by a thorough analysis of the influence of criti
Publikováno v:
Nanotechnology
Nanotechnology, 2017, 28 (33), 335702, 11 p. ⟨10.1088/1361-6528/aa7a36⟩
Nanotechnology, Institute of Physics, 2017, 28 (33), 335702, 11 p. ⟨10.1088/1361-6528/aa7a36⟩
Nanotechnology, 2017, 28 (33), 335702, 11 p. ⟨10.1088/1361-6528/aa7a36⟩
Nanotechnology, Institute of Physics, 2017, 28 (33), 335702, 11 p. ⟨10.1088/1361-6528/aa7a36⟩
International audience; In this paper, a broadband non-destructive and non-contact local characterization of graphene fabricated by epitaxial method on silicon carbide is demonstrated by using an interferometerbased near-field microwave microscope. F
Publikováno v:
2017 IEEE Topical Conference on Wireless Sensors and Sensor Networks (WiSNet).
In this paper a six-port reflectometer to be included in a near-field microwave microscope (NFMM) is presented. The reflectometer, made of five couplers based on non-uniform and offset parallel-coupled transmission lines, is proposed to achieve a bro
Publikováno v:
46th European Microwave Conference, EuMC 2016
46th European Microwave Conference, EuMC 2016, Oct 2016, London, United Kingdom. pp.544-547, ⟨10.1109/EuMC.2016.7824400⟩
46th European Microwave Conference, EuMC 2016, Oct 2016, London, United Kingdom. pp.544-547, ⟨10.1109/EuMC.2016.7824400⟩
International audience; A near-field scanning microwave microscope based on an interferometric technique is proposed in this work. To ensure an optimal spatial resolution, crucial parameters of the evanescent microwave probe are finely studied includ
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::eb95ce694fed6ab29a8d0bd933a5ab97
https://hal.science/hal-03538364
https://hal.science/hal-03538364
Publikováno v:
2016 Progress in Electromagnetic Research Symposium (PIERS).
Near-field scanning microwave microscope (NFSMM) has potentials to achieve characterizations of materials with high spatial resolution and sensitivity. A wide range of applications have been addressed such as dielectric constant measurement, impedanc
Publikováno v:
Applied Physics Letters
Applied Physics Letters, 2016, 108 (24), pp.242903. ⟨10.1063/1.4953629⟩
Applied Physics Letters, 2016, 108 (24), pp.242903. ⟨10.1063/1.4953629⟩
International audience; The complex dielectric permittivity of aqueous saline solutions has been determined in the frequency range [2-18 GHz] with a home-made near-field microwave microscope. The instrument is built on a vector network analyzer, a ma
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::bca23b49e7600aabbe14979a9ec44b30
https://hal.science/hal-03538486/document
https://hal.science/hal-03538486/document
Publikováno v:
Measurement Science and Technology
Measurement Science and Technology, 2017, 28 (1), pp.014014. ⟨10.1088/1361-6501/28/1/014014⟩
Measurement Science and Technology, 2017, 28 (1), pp.014014. ⟨10.1088/1361-6501/28/1/014014⟩
International audience; Saline solutions are of a great interest when characterizations of biological fluids are targeted. In this work a near-field microwave microscope is proposed for the characterization of liquids. An interferometric technique is