Zobrazeno 1 - 10
of 23
pro vyhledávání: '"Thomas L. Ferrell"'
Autor:
Thomas L. Ferrell, O. Aldaghri, Fabrice Meriaudeau, Fahad Usman, John Ojur Dennis, E.M. Mkawi, Yas Al-Hadeethi, Abdelmoneim Sulieman
Publikováno v:
Polymers
Volume 12
Issue 11
Polymers, Vol 12, Iss 2750, p 2750 (2020)
Volume 12
Issue 11
Polymers, Vol 12, Iss 2750, p 2750 (2020)
This work reports the use of a ternary composite that integrates p-Toluene sulfonic acid doped polyaniline (PANI), chitosan, and reduced graphene oxide (RGO) as the active sensing layer of a surface plasmon resonance (SPR) sensor. The SPR sensor is i
Publikováno v:
Applied optics. 57(9)
In apertureless scanning-probe optical microscopy and in the case of more traditional scanned optical probes coated with a metal that is thin near the probe tip (in lieu of an aperture), samples are probed via interaction between the probe and surfac
Autor:
Anthony C Gehl, Bernadeta R. Srijanto, Christine P. Cheney, Marilyn A. Huestis, Thomas L. Ferrell, P.B. Crilly, D. L. Hedden
Publikováno v:
Sensor Letters. 10:850-855
Publikováno v:
Physics Today. 71:65-65
Publikováno v:
Sensors and Actuators B: Chemical. 114:206-211
Microcalorimetric optical and infrared spectroscopy is a method of determining the spectral absorption of small quantities of materials over a wide range of incident wavelengths. In this paper, the first spectroscopic results for microcantilevers coa
Autor:
D. L. McCorkle, Sanjay V. Patel, Todd E. Mlsna, Thomas L. Ferrell, S. R. Hunter, Robert J. Warmack
Publikováno v:
Sensors and Actuators B: Chemical. 107:892-903
A technique for the measurement of ethanol concentrations in aqueous mixtures is reported, in which a permeable membrane is used to transport ethanol vapors to a microelectromechanical (MEMS) chemi-capacitor array. The fixed plate micro-capacitors we
Publikováno v:
Langmuir. 19:7514-7520
Biomolecular conformational differences of oligomeric nucleic acids were discerned using scanning Kelvin probe (SKP) analysis in an array format on gold-coated silicon substrates. Variations in work function, measured as contact potential difference,
Autor:
Sherwin Kouchekian, Thomas Thundat, Govindarajan Muralidharan, Thomas L. Ferrell, Suman Cherian, Adosh Mehta, Ali Passian
Publikováno v:
Journal of Applied Physics. 91:4693-4700
The small amplitude thermal vibrations of the microcantilever of an atomic force microscope can be enhanced via a delayed feedback system. This is verified experimentally for a triangular cantilever, and modeled theoretically as a boundary value prob
Publikováno v:
Optics & Laser Technology. 31:273-277
The eAect of variation of core and cladding index diAerence, Dna ncorencladding, on allowable values for the guided mode transverse magnetic propagation constants within a step-index, multi-mode optical fiber is investigated. We use a iterative compu
Publikováno v:
Microscopy Today. 7:14-17
The use of traditional optics in microscopy has a well-known resolution barrier first presented by Lord Rayleigh. This is the "Rayleigh diffraction limit." In the usual textbook example, the overlapping diffraction rings from two small objects are se