Zobrazeno 1 - 10
of 38
pro vyhledávání: '"Th. Sluyters"'
Autor:
Th. Sluyters, J. G. Alessi
Publikováno v:
Review of Scientific Instruments. 51:1630-1633
A significant improvement in the performance of the BNL Mark III magnetron negative ion sources has been achieved by putting cylindrical grooves on the cathode to geometrically focus surface produced H− and D− ions into the emission slit in the a
Publikováno v:
Journal of Applied Physics. 48:2668-2672
Energy spectra of H− ions from a HDD source operating in mixtures of helium, hydrogen, and cesium reveal that negative ions are generated by a volume process and by a surface process. A marked difference was observed in the pressure dependence of t
Autor:
Steven Tepikian, S. Giordano, A. D. Krisch, P.A. Montemurro, R. R. Raylman, R. J. Nawrocky, A. M. T. Lin, S. Y. Lee, M. Fujisaki, Ahovi Kponou, Tatsushi Shima, Jay Roberts, Y.Y. Lee, J. F. Skelly, R. L. Witkover, F.Z. Khiari, G. T. Danby, H. J. Halama, G. R. Court, P. R. Cameron, L. G. Ratner, Th. Sluyters, M. Simonius, J. A. Bywater, D. Peaslee, D. G. Crabb, Thomas Roser, Kent M. Terwilliger, E. D. Courant, R. Lockey, R. L. Martin, L. C. Northcliffe, A. Soukas, M. E. Hejazifar, R. Lambiase, G.C. Phillips, R. S. Raymond, V. W. Hughes, L.A. Ahrens, J. R. O'Fallon, S. L. Linn, T. S. Bhatia, Kevin Brown, Yousef Makdisi, Peter Hansen, I. Gialas, J. G. Alessi, H. N. Brown, P. Schüler
Publikováno v:
Physical Review D. 39:45-85
Accelerating polarized protons to 22 GeV/c at the Brookhaven Alternating Gradient Synchro- tron required both extensive hardware modifications and a difficult commissioning process. We had to overcome 45 strong depolarizing resonances to maintain pol
Publikováno v:
Review of Scientific Instruments. 55:8-11
Maintaining the proper low work function surface in steady‐state high‐current‐density negative ion sources is difficult, due to intense ion bombardment of the surface. Experiments were performed in which liquid cesium was forced through a porou
Publikováno v:
Review of Scientific Instruments. 47:1425-1434
A parametric study was made of the pulsed hollow discharge duoplasmatron, operating as a negative hydrogen ion source in the pure hydrogen mode and in the mixed hydrogen–cesium mode. Effects of the arc current, gas pressure, and the magnetic field
Publikováno v:
IEEE Transactions on Nuclear Science. 16:221-226
Publikováno v:
IEEE Transactions on Nuclear Science. 14:1143-1150
A device is described with which one can measure total and partial horizontal or vertical emittances in shorter than 40 ?s.
Autor:
Th. Sluyters, K. Prelec
Publikováno v:
Review of Scientific Instruments. 44:1451-1463
The article represents a review of direct extraction sources of negative hydrogen ions. During the past year or so interest in this method of producing high intensity beams of negative ions has increased considerably because of new developments resul
Autor:
Th. Sluyters
Publikováno v:
Nuclear Instruments and Methods. 27:301-305
A simple emittance measuring technique using emulsion detection has been applied to determine proton beam qualities up to 50 MeV and beam intensities up to 300 mA per 10 μsec. The evolution of beam emittances along the linear accelerator has been di
Autor:
Th. Sluyters, E. de Haas
Publikováno v:
Review of Scientific Instruments. 29:597-600
In order to get information about the excitation processes in a discharge tube, a spectrograph has been built, which scans the range between the visible and the far ultraviolet. Using a Paschen‐Runge mounting the spectrum has been detected with a c