Nico F. de Rooij, Peter Vettiger, Tomonobu Nakayama, Sebastian Gautsch, Kota Shiba, Frederic Loizeau, Terunobu Akiyama, Genki Yoshikawa, Masakazu Aono
Publikováno v:
Sensors, Vol 12, Iss 11, Pp 15873-15887 (2012)
We present a new generation of piezoresistive nanomechanical Membrane-type Surface stress Sensor (MSS) chips, which consist of a two dimensional array of MSS on a single chip. The implementation of several optimization techniques in the design and mi
Externí odkaz:
https://doaj.org/article/0daf0a7ebfa74fa593c2c34123725548
Autor:
Hans Peter Lang, Frédéric Loizeau, Agnès Hiou-Feige, Jean-Paul Rivals, Pedro Romero, Terunobu Akiyama, Christoph Gerber, Ernst Meyer
Publikováno v:
Sensors, Vol 16, Iss 7, p 1149 (2016)
For many diseases, where a particular organ is affected, chemical by-products can be found in the patient’s exhaled breath. Breath analysis is often done using gas chromatography and mass spectrometry, but interpretation of results is difficult and
Externí odkaz:
https://doaj.org/article/f4cbff7b764f43de84b6ad8969836cb1
Autor:
Terunobu Akiyama, Genki Yoshikawa
Publikováno v:
2019 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN).
The development of novel receptor materials for chemical sensors would trigger a breakthrough in the field of odor/gas sensing. To encourage more researchers to start R&Ds on this subject, useful peripheral tools and sensor devices should be availabl
Autor:
Genki Yoshikawa, Nico F. de Rooij, Frédéric Loizeau, Terunobu Akiyama, Sebastian Gautsch, Peter Vettiger
Publikováno v:
Sensors and Actuators A: Physical. 228:9-15
Point-of-care (PoC) applications require small, fast, and low power sensors with high reliability. Despite showing promising performances, nanomechanical sensors have not yet demonstrated the excellent reproducibility of measurements necessary to be
Publikováno v:
Sensors and Actuators A: Physical. 215:184-188
A new and versatile fabrication process of insulated gold tip probes for atomic force microscopy (AFM) is presented by Wu et al. (In-plane fabricated insulated gold-tip probe for electrochemical and molecular experiments, in: 2013 IEEE 26th Internati
Autor:
Sebastian Gautsch, Frédéric Loizeau, Kota Shiba, Genki Yoshikawa, Nico F. de Rooij, Peter Vettiger, Cory J. Y. Lee, Tomonobu Nakayama, Terunobu Akiyama, Masakazu Aono
Publikováno v:
Langmuir. 29:7551-7556
With their capability for real-time and label-free detection of targets ranging from gases to biological molecules, nanomechanical sensors are expected to contribute to various fields, such as medicine, security, and environmental science. For practi
Publikováno v:
ECS Transactions. 50:465-468
Measuring the mechanical properties of molecule junctions and, in parallel, recording their electric response provides further insight for molecular electronics. On the other hand, the Conductive Probe (CP-AFM) experiments with electrochemically cont
Autor:
Tomonobu Nakayama, Genki Yoshikawa, Masakazu Aono, Nico F. de Rooij, Peter Vettiger, Kota Shiba, Terunobu Akiyama, Frédéric Loizeau, Sebastian Gautsch
Publikováno v:
Sensors; Volume 12; Issue 11; Pages: 15873-15887
Sensors, Vol 12, Iss 11, Pp 15873-15887 (2012)
Sensors (Basel, Switzerland)
Sensors, Vol 12, Iss 11, Pp 15873-15887 (2012)
Sensors (Basel, Switzerland)
We present a new generation of piezoresistive nanomechanical Membrane-type Surface stress Sensor (MSS) chips, which consist of a two dimensional array of MSS on a single chip. The implementation of several optimization techniques in the design and mi
Autor:
Frédéric Loizeau, Jean-Paul Rivals, Agnès Hiou, Hans Peter Lang, Pedro Romero, Terunobu Akiyama, Ernst Meyer, Christoph Gerber
Publikováno v:
Sensors, Vol 16, Iss 7, p 1149 (2016)
Sensors (Basel, Switzerland)
Sensors; Volume 16; Issue 7; Pages: 1149
Sensors, vol. 16, no. 7
Sensors (Basel, Switzerland)
Sensors; Volume 16; Issue 7; Pages: 1149
Sensors, vol. 16, no. 7
For many diseases, where a particular organ is affected, chemical by-products can be found in the patient’s exhaled breath. Breath analysis is often done using gas chromatography and mass spectrometry, but interpretation of results is difficult and
Publikováno v:
Procedia Engineering. 25:1513-1516
We report on harsh-environment-compatible Pt-TSVs forming ohmic contacts with a highly doped bulk silicon. They were developed as a part of a Single Wall Carbone NanoTube (SWCNT) resonator device with 3D-packaging. The fundamental properties of the T